<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Archiwa C2000+ - Induprogress</title>
	<atom:link href="https://induprogress.pl/tag/c2000/feed/" rel="self" type="application/rss+xml" />
	<link>https://induprogress.pl/tag/c2000/</link>
	<description></description>
	<lastBuildDate>Fri, 13 Mar 2026 11:28:28 +0000</lastBuildDate>
	<language>pl-PL</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://induprogress.pl/wp-content/uploads/2024/10/fav-100x100.png</url>
	<title>Archiwa C2000+ - Induprogress</title>
	<link>https://induprogress.pl/tag/c2000/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Konfiguracja komunikacji przez Modbus w falownikach serii C2000</title>
		<link>https://induprogress.pl/artykuly-techniczne/konfiguracja-komunikacji-przez-modbus-w-falownikach-serii-c2000/</link>
					<comments>https://induprogress.pl/artykuly-techniczne/konfiguracja-komunikacji-przez-modbus-w-falownikach-serii-c2000/#respond</comments>
		
		<dc:creator><![CDATA[Aleksandra Puzon]]></dc:creator>
		<pubDate>Thu, 20 Nov 2025 11:29:08 +0000</pubDate>
				<category><![CDATA[Artykuły techniczne]]></category>
		<category><![CDATA[Technika napędowa]]></category>
		<category><![CDATA[C2000+]]></category>
		<category><![CDATA[falownik]]></category>
		<category><![CDATA[modbus]]></category>
		<guid isPermaLink="false">https://induprogress.pl/?p=28394</guid>

					<description><![CDATA[<p>W niniejszym artykule przedstawiono sposób okablowania i konfigurację komunikacji Modbus na przykładzie falownika serii C2000</p>
<p>Artykuł <a href="https://induprogress.pl/artykuly-techniczne/konfiguracja-komunikacji-przez-modbus-w-falownikach-serii-c2000/">Konfiguracja komunikacji przez Modbus w falownikach serii C2000</a> pochodzi z serwisu <a href="https://induprogress.pl">Induprogress</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" class="vc_single_image-img " src="https://induprogress.pl/wp-content/uploads/2024/11/artykuly-techniczne-banner.jpg" width="1080" height="280" alt="artykuły techniczne induprogress" title="artykuły techniczne banner" loading="lazy" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Konfiguracja komunikacji</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Wszystkie falowniki Delta Electronics posiadają wbudowany port komunikacyjny Modbus. W niniejszym artykule przedstawiono sposób okablowania i konfigurację komunikacji Modbus na przykładzie falownika serii <strong><a href="https://induprogress.pl/kategoria-produktu/technika-napedowa/przemienniki-czestotliwosci/falowniki-serii-vfd-c2000-przemienniki-czestotliwosci/">C2000</a></strong>.</p>

		</div>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Okablowanie</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Falownik C2000 posiada jeden port komunikacyjny Modbus. Z tego portu wyprowadzono trzy porty fizyczne Modbus RS-485. Dzięki temu wygodniej można podpiąć falownik szeregowo do magistrali Modbus. Złącza Modbus są opisane SG+, SG-, SGND.</p>
<p>Pierwszy port ma postać złącz śrubowych. Na rys. poniżej złącza Modbus znajdują się na dole, po prawej stronie.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="805" height="331" src="https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_1.jpg" class="vc_single_image-img attachment-large" alt="konfiguracja komunikacji przez modbus_1" title="konfiguracja komunikacji przez modbus_1" srcset="https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_1.jpg 805w, https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_1-300x123.jpg 300w, https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_1-768x316.jpg 768w, https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_1-600x247.jpg 600w" sizes="(max-width: 805px) 100vw, 805px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Dwa kolejne porty Modbus są portami RJ-45. Do komunikacji są wykorzystywane piny 4 (SG-), 5 (SG+). Piny 3 i 6 należy podłączyć do SGND. Porty Modbus znajdują się na prawo od złącz śrubowych opisanych powyżej.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="458" height="446" src="https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_2.jpg" class="vc_single_image-img attachment-large" alt="konfiguracja komunikacji przez modbus_2" title="konfiguracja komunikacji przez modbus_2" srcset="https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_2.jpg 458w, https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_2-300x292.jpg 300w" sizes="(max-width: 458px) 100vw, 458px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>Uwaga!</strong></p>
<p>Podczas podłączania kabli do złącz RJ-45 należy pamiętać, że część falowników ma zabudowane porty komunikacyjne CANOpen. Podłączenie sieci Modbus do portu CANOpen nie pozwoli na nawiązanie komunikacji. Na zdjęciu poniżej zaznaczono porty CANOpen i Modbus.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="851" height="1024" src="https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_3-851x1024.jpg" class="vc_single_image-img attachment-large" alt="konfiguracja komunikacji przez modbus_3" title="konfiguracja komunikacji przez modbus_3" srcset="https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_3-851x1024.jpg 851w, https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_3-249x300.jpg 249w, https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_3-768x924.jpg 768w, https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_3-600x722.jpg 600w, https://induprogress.pl/wp-content/uploads/2025/11/konfiguracja-komunikacji-przez-modbus_3.jpg 1052w" sizes="(max-width: 851px) 100vw, 851px" /></div>
		</figure>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Parametry komunikacji</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Parametry komunikacji Modbus są ustawiane w grupie 9 parametrów. W poniższej tabeli przedstawiono podstawowe parametry.</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<table width="993">
<tbody>
<tr>
<td width="123"><strong>Parametr</strong></td>
<td width="250"><strong>Opis</strong></td>
<td width="412"><strong>Ustawienia</strong></td>
</tr>
<tr>
<td width="123"><strong>09-00</strong></td>
<td width="250">Adres komunikacyjny COM1</td>
<td width="412">1~254</td>
</tr>
<tr>
<td width="123"><strong>09-01</strong></td>
<td width="250">Prędkość transmisji</td>
<td width="412">4,8~115,2 kbps</td>
</tr>
<tr>
<td width="123"><strong>09-02</strong></td>
<td width="250">Reakcja napędu na błąd transmisji</td>
<td width="412">0: Ostrzeżenie i kontynuacja pracy<br />
1: Ostrzeżenie i hamowanie z uwzględnieniem czasu hamowania<br />
2: Ostrzeżenie i hamowanie wybiegiem<br />
3: Kontynuacja pracy bez ostrzeżenia</td>
</tr>
<tr>
<td width="123"><strong>09-03</strong></td>
<td width="250">Czas detekcji utraty komunikacji (timeout)</td>
<td width="412">0,0~100,0 s</td>
</tr>
<tr>
<td width="123"><strong>09-04</strong></td>
<td width="250">Protokół komunikacji</td>
<td width="412">1: 7N2 (ASCII)<br />
2: 7E1 (ASCII)<br />
3: 7O1 (ASCII)<br />
4: 7E2 (ASCII)<br />
5: 7O2 (ASCII)<br />
6: 8N1 (ASCII)<br />
7: 8N2 (ASCII)<br />
8: 8E1 (ASCII)<br />
9: 8O1 (ASCII)<br />
10: 8E2 (ASCII)<br />
11: 8O2 (ASCII)<br />
12: 8N1 (RTU)<br />
13: 8N2 (RTU)<br />
14: 8E1 (RTU)<br />
15: 8O1 (RTU)<br />
16: 8E2 (RTU)<br />
17: 8O2 (RTU)</td>
</tr>
<tr>
<td width="123"><strong>09-35</strong></td>
<td width="250">Adres komunikacyjny PLC</td>
<td width="412">1~254</td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Z powyższej tabeli wynika, że parametr 09-00 jest adresem falownika, natomiast adres wbudowanego PLC można ustawić w parametrze 09-35. Należy pamiętać, że adresy wszystkich urządzeń w sieci Modbus muszą być unikalne.</p>
<p>&nbsp;</p>
<p><strong>Przykład 1.</strong> Ustawienie protokołu Modbus ASCII 7, N, 2 i prędkości transmisji 9600 bps wymaga ustawienia parametrów:</p>
<ul>
<li>09-01 = 9.6</li>
<li>09-04 = 1</li>
</ul>
<p><strong>Przykład 2</strong>. Aby falownik po 3 sekundach od utraty komunikacji hamował wybiegiem i zgłaszał alarm należy ustawić parametry:</p>
<ul>
<li>09-02 = 3</li>
<li>09-03 = 3.0</li>
</ul>

		</div>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Adresy Modbus falownika C2000</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Wszystkie parametry falownika są dostępne dla protokołu Modbus. Adres Modbus parametru składa się z numeru grupy i numeru parametru. Adres w zapisie heksadecymalnym ma postać:</p>
<p>GGnn, gdzie GG – numer grupy, nn – numer parametru</p>
<p>&nbsp;</p>
<p><strong>Przykłady:</strong></p>
<ul>
<li>Parametr 04-01 ma adres 0x0401,</li>
<li>Parametr 10-23 ma adres 0x0A17.</li>
</ul>
<p>W poniższej tabeli przedstawiono słowa sterujące i statusy pracy, które również są dostępne poprzez Modbus.</p>
<p>Aby sterować pracą falownika przez komunikację Modbus, należy ustawić następujące parametry:</p>
<ul>
<li>00-20 = 1 zadawanie częstotliwości w trybie AUTO przez RS-485,</li>
<li>00-21 = 2 sterowanie pracą w trybie AUTO przez RS-485.</li>
</ul>
<p>&nbsp;</p>
<p><strong><em>Słowa sterujące</em></strong></p>
<p>W poniższej tabeli podano wszystkie słowa sterujące</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<table width="1006">
<thead>
<tr>
<td width="133"><strong>Adres (hex)</strong></td>
<td colspan="2" width="839"><strong>Funkcja</strong></td>
</tr>
</thead>
<tbody>
<tr>
<td width="133"><strong>2000</strong></td>
<td width="110">Bit 1~0</td>
<td width="713">00: Brak funkcji<br />
01: STOP<br />
10: RUN<br />
11: JOG+RUN</td>
</tr>
<tr>
<td width="133"></td>
<td width="110">Bit 3~2</td>
<td width="713">Zarezerwowano</td>
</tr>
<tr>
<td width="133"></td>
<td width="110">Bit 5~4</td>
<td width="713">00: Brak funkcji<br />
01: FWD<br />
10: REV<br />
11: Zmiana kierunku</td>
</tr>
<tr>
<td width="133"><strong>2000</strong></td>
<td width="110">Bit 7~6</td>
<td width="713">00: Wybór 1. zestawu czasów przyspieszania/zwalniania<br />
01: Wybór 2. zestawu czasów przyspieszania/zwalniania<br />
10: Wybór 3. zestawu czasów przyspieszania/zwalniania<br />
11: Wybór 4. zestawu czasów przyspieszania/zwalniania</td>
</tr>
<tr>
<td width="133"></td>
<td width="110">Bit 11~8</td>
<td width="713">0000: Wybór głównej częstotliwości<br />
0001: Wybór 1. częstotliwości<br />
0010: Wybór 2. częstotliwości<br />
0011: Wybór 3. Częstotliwości<br />
0100: Wybór 4. częstotliwości<br />
0101: Wybór 5. częstotliwości<br />
0110: Wybór 6. częstotliwości<br />
0111: Wybór 7. Częstotliwości<br />
1000: Wybór 8. częstotliwości<br />
1001: Wybór 9. częstotliwości<br />
1010: Wybór 10. częstotliwości<br />
1011: Wybór 11. Częstotliwości<br />
1100: Wybór 12. częstotliwości<br />
1101: Wybór 13. częstotliwości<br />
1110: Wybór 14. częstotliwości<br />
1111: Wybór 15. częstotliwości</td>
</tr>
<tr>
<td width="133"></td>
<td width="110">Bit 12</td>
<td width="713">1: Załączenie funkcji z bitów 11~6</td>
</tr>
<tr>
<td width="133"></td>
<td width="110">Bit 14~13</td>
<td width="713">00: Brak funkcji<br />
01: Sterowanie przez panel<br />
10: Sterowanie zgodnie z parametrem 00-21<br />
11: Zmiana sterowania</td>
</tr>
<tr>
<td width="133"></td>
<td width="110">Bit 15</td>
<td width="713">Zarezerwowano</td>
</tr>
<tr>
<td width="133"><strong>2001</strong></td>
<td width="110"></td>
<td width="713">Częstotliwość zadana z dokładnością do 0,01 Hz</td>
</tr>
<tr>
<td rowspan="4" width="133"><strong>2002</strong></td>
<td width="110">Bit 0</td>
<td width="713">1: Awaria (EF)</td>
</tr>
<tr>
<td width="110">Bit 1</td>
<td width="713">1: Reset awarii</td>
</tr>
<tr>
<td width="110">Bit 2</td>
<td width="713">1: Załączenie stanu bazowego (Base Block)</td>
</tr>
<tr>
<td width="110">Bit 15~3</td>
<td width="713">Zarezerwowano</td>
</tr>
</tbody>
</table>

		</div>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Podstawowe słowa statusu (tylko do odczytu)</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>W poniższej tabeli przedstawiono podstawowe słowa statusu. Opis pozostałych znajduje się w instrukcji.</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<table width="1028">
<tbody>
<tr>
<td width="136"><strong>Adres (hex)</strong></td>
<td colspan="2" width="858"><strong>Funkcja</strong></td>
</tr>
<tr>
<td rowspan="2" width="136"><strong>2100</strong></td>
<td width="113">Bit 15~8</td>
<td width="729">Kod ostrzeżenia</td>
</tr>
<tr>
<td width="113">Bit 7~0</td>
<td width="729">Kod błędu</td>
</tr>
<tr>
<td rowspan="10" width="136"><strong>2101</strong></td>
<td width="113">Bit 1~0</td>
<td width="729">Stan napędu<br />
00: Zatrzymany<br />
01: Hamowanie<br />
10: Oczekiwanie (standby)<br />
11: Praca</td>
</tr>
<tr>
<td width="113">Bit 2</td>
<td width="729">1: JOG</td>
</tr>
<tr>
<td width="113">Bit 4~3</td>
<td width="729">Kierunek<br />
00: FWD<br />
01: REV-&gt;FWD<br />
10: REV<br />
11: FWD-&gt;REV</td>
</tr>
<tr>
<td width="113">Bit 7~5</td>
<td width="729">Zarezerwowano</td>
</tr>
<tr>
<td width="113">Bit 8</td>
<td width="729">1: Częstotliwość zadawana przez komunikację</td>
</tr>
<tr>
<td width="113">Bit 9</td>
<td width="729">1: Częstotliwość zadawana przez sygnał analogowy</td>
</tr>
<tr>
<td width="113">Bit 10</td>
<td width="729">1: Sterowanie przez komunikację</td>
</tr>
<tr>
<td width="113">Bit 11</td>
<td width="729">1: Blokada parametrów</td>
</tr>
<tr>
<td width="113">Bit 12</td>
<td width="729">1: Zezwolenie na zgrywanie parametrów z panelu</td>
</tr>
<tr>
<td width="113">Bit 15~13</td>
<td width="729">Zarezerwowano</td>
</tr>
<tr>
<td width="136"><strong>2102</strong></td>
<td width="113"></td>
<td width="729">Częstotliwość zadana (0,01 Hz)</td>
</tr>
<tr>
<td width="136"><strong>2103</strong></td>
<td width="113"></td>
<td width="729">Częstotliwość wyjściowa (0,01 Hz)</td>
</tr>
<tr>
<td width="136"><strong>2104</strong></td>
<td width="113"></td>
<td width="729">Prąd wyjściowy. Jeżeli nie jest większy niż 655,35 A to dokładność wynosi 0,01A. Jeżeli prąd jest większy to dokładność wynosi 0,1 A.</td>
</tr>
<tr>
<td width="136"><strong>2105</strong></td>
<td width="113"></td>
<td width="729">Napięcie szyny DC (0,1 V)</td>
</tr>
<tr>
<td width="136"><strong>2106</strong></td>
<td width="113"></td>
<td width="729">Napięcie wyjściowe (0,1 V)</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><em>Opublikowano: 9 stycznia 2018</em></p>

		</div>
	</div>
</div></div></div></div>
</div><p>Artykuł <a href="https://induprogress.pl/artykuly-techniczne/konfiguracja-komunikacji-przez-modbus-w-falownikach-serii-c2000/">Konfiguracja komunikacji przez Modbus w falownikach serii C2000</a> pochodzi z serwisu <a href="https://induprogress.pl">Induprogress</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://induprogress.pl/artykuly-techniczne/konfiguracja-komunikacji-przez-modbus-w-falownikach-serii-c2000/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Jak skonfigurować Profinet w falownikach serii C2000+</title>
		<link>https://induprogress.pl/artykuly-techniczne/jak-skonfigurowac-profinet-w-falownikach-serii-c2000/</link>
					<comments>https://induprogress.pl/artykuly-techniczne/jak-skonfigurowac-profinet-w-falownikach-serii-c2000/#respond</comments>
		
		<dc:creator><![CDATA[Aleksandra Puzon]]></dc:creator>
		<pubDate>Tue, 18 Nov 2025 14:48:58 +0000</pubDate>
				<category><![CDATA[Artykuły techniczne]]></category>
		<category><![CDATA[Technika napędowa]]></category>
		<category><![CDATA[C2000+]]></category>
		<category><![CDATA[CMC-PN01]]></category>
		<category><![CDATA[Profinet]]></category>
		<guid isPermaLink="false">https://induprogress.pl/?p=28364</guid>

					<description><![CDATA[<p>Artykuł zawiera konfigurację połączenia pomiędzy falownikiem C2000+ posiadającym kartę komunikacyjną CMC-PN01</p>
<p>Artykuł <a href="https://induprogress.pl/artykuly-techniczne/jak-skonfigurowac-profinet-w-falownikach-serii-c2000/">Jak skonfigurować Profinet w falownikach serii C2000+</a> pochodzi z serwisu <a href="https://induprogress.pl">Induprogress</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" class="vc_single_image-img " src="https://induprogress.pl/wp-content/uploads/2024/11/artykuly-techniczne-banner.jpg" width="1080" height="280" alt="artykuły techniczne induprogress" title="artykuły techniczne banner" loading="lazy" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Konfigurowanie Profinet w falownikach serii C2000+</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Artykuł zawiera konfigurację połączenia pomiędzy falownikiem <strong><a href="https://induprogress.pl/kategoria-produktu/technika-napedowa/przemienniki-czestotliwosci/falowniki-serii-vfd-c2000/">C2000+</a> </strong>posiadającym kartę komunikacyjną CMC-PN01, a sterownikiem Siemens S7-1200 po Profinecie. Do sterowania falownikiem wykorzystane zostały adresy Modbus z grupy 60xxH. Omówione zostało sterowanie w trybie prędkościowym, momentowym i pozycyjnym.</p>
<p>Software:<br />
TIAPortal V17.1</p>
<p>MS300 v2.01</p>
<p>CMC-PN01 v9.03</p>

		</div>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">1. Konfiguracja po stronie falownika C2000+ z kartą komunikacyjną CMC-PN01</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>W poniższej instrukcji przedstawiona została komunikacja z wykorzystaniem adresów 60xxH falownika. Aby aktywować metodę dekodowana odpowiednią dla adresów 60xxH należy wpisać do parametru 09-30 wartość „1”.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="608" height="243" src="https://induprogress.pl/wp-content/uploads/2025/11/A8_1.png" class="vc_single_image-img attachment-large" alt="profinet w falownikach C2000+_1" title="profinet w falownikach C2000+_1" srcset="https://induprogress.pl/wp-content/uploads/2025/11/A8_1.png 608w, https://induprogress.pl/wp-content/uploads/2025/11/A8_1-300x120.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/A8_1-600x240.png 600w" sizes="(max-width: 608px) 100vw, 608px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Następnie należy ustawić parametry:</p>
<p>00-20 na wartość 8 – źródło częstotliwości zadanej z karty komunikacyjnej</p>
<p>00-21 na wartość 5 – źródło komendy RUN z karty komunikacyjnej</p>
<p>09-60 – ten parametr powinien wskazywać wartość 12 jeżeli karta została podłączona prawidłowo</p>

		</div>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">2. Konfiguracja po stronie sterownika S7-1200</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>2.1 Tworzymy nowy projekt w TIA portal oraz dodajemy sterownik CPU.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1024" height="668" src="https://induprogress.pl/wp-content/uploads/2025/11/A8_2-1024x668.png" class="vc_single_image-img attachment-large" alt="profinet w falownikach C2000+_2" title="profinet w falownikach C2000+_2" srcset="https://induprogress.pl/wp-content/uploads/2025/11/A8_2-1024x668.png 1024w, https://induprogress.pl/wp-content/uploads/2025/11/A8_2-300x196.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/A8_2-768x501.png 768w, https://induprogress.pl/wp-content/uploads/2025/11/A8_2-420x275.png 420w, https://induprogress.pl/wp-content/uploads/2025/11/A8_2-600x391.png 600w, https://induprogress.pl/wp-content/uploads/2025/11/A8_2.png 1334w" sizes="(max-width: 1024px) 100vw, 1024px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>2.2 Następnie do naszego projektu należy dodać plik konfiguracyjny GSD do naszej karty. Plik dostępny jest do pobrania ze strony producenta.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1024" height="631" src="https://induprogress.pl/wp-content/uploads/2025/11/A8_3-1024x631.png" class="vc_single_image-img attachment-large" alt="profinet w falownikach C2000+_3" title="profinet w falownikach C2000+_3" srcset="https://induprogress.pl/wp-content/uploads/2025/11/A8_3-1024x631.png 1024w, https://induprogress.pl/wp-content/uploads/2025/11/A8_3-300x185.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/A8_3-768x473.png 768w, https://induprogress.pl/wp-content/uploads/2025/11/A8_3-600x370.png 600w, https://induprogress.pl/wp-content/uploads/2025/11/A8_3.png 1396w" sizes="(max-width: 1024px) 100vw, 1024px" /></div>
		</figure>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1024" height="595" src="https://induprogress.pl/wp-content/uploads/2025/11/A8_4-1024x595.png" class="vc_single_image-img attachment-large" alt="profinet w falownikach C2000+_4" title="profinet w falownikach C2000+_4" srcset="https://induprogress.pl/wp-content/uploads/2025/11/A8_4-1024x595.png 1024w, https://induprogress.pl/wp-content/uploads/2025/11/A8_4-300x174.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/A8_4-768x446.png 768w, https://induprogress.pl/wp-content/uploads/2025/11/A8_4-600x348.png 600w, https://induprogress.pl/wp-content/uploads/2025/11/A8_4.png 1252w" sizes="(max-width: 1024px) 100vw, 1024px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>2.3 W ustawieniach sterownika przydzielamy mu statyczny adres IP oraz udzielamy dostępu do opcji PUT/GET wymiany danych.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1024" height="868" src="https://induprogress.pl/wp-content/uploads/2025/11/A8_5-1024x868.png" class="vc_single_image-img attachment-large" alt="profinet w falownikach C2000+_5" title="profinet w falownikach C2000+_5" srcset="https://induprogress.pl/wp-content/uploads/2025/11/A8_5-1024x868.png 1024w, https://induprogress.pl/wp-content/uploads/2025/11/A8_5-300x254.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/A8_5-768x651.png 768w, https://induprogress.pl/wp-content/uploads/2025/11/A8_5-600x509.png 600w, https://induprogress.pl/wp-content/uploads/2025/11/A8_5.png 1130w" sizes="(max-width: 1024px) 100vw, 1024px" /></div>
		</figure>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1024" height="559" src="https://induprogress.pl/wp-content/uploads/2025/11/A8_6-1024x559.png" class="vc_single_image-img attachment-large" alt="profinet w falownikach C2000+_6" title="profinet w falownikach C2000+_6" srcset="https://induprogress.pl/wp-content/uploads/2025/11/A8_6-1024x559.png 1024w, https://induprogress.pl/wp-content/uploads/2025/11/A8_6-300x164.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/A8_6-768x419.png 768w, https://induprogress.pl/wp-content/uploads/2025/11/A8_6-600x328.png 600w, https://induprogress.pl/wp-content/uploads/2025/11/A8_6.png 1533w" sizes="(max-width: 1024px) 100vw, 1024px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>2.4 Kolejnym krokiem jest dodanie karty do sieci Profinet. Aby to zrobić należy przejść do widoku Network view, a następnie wybrać kartę w oknie Hardware catalog i przeciągnąć do okna z widokiem sieci.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1024" height="355" src="https://induprogress.pl/wp-content/uploads/2025/11/A8_7-1024x355.png" class="vc_single_image-img attachment-large" alt="profinet w falownikach C2000+_7" title="profinet w falownikach C2000+_7" srcset="https://induprogress.pl/wp-content/uploads/2025/11/A8_7-1024x355.png 1024w, https://induprogress.pl/wp-content/uploads/2025/11/A8_7-300x104.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/A8_7-768x266.png 768w, https://induprogress.pl/wp-content/uploads/2025/11/A8_7-1536x533.png 1536w, https://induprogress.pl/wp-content/uploads/2025/11/A8_7-600x208.png 600w, https://induprogress.pl/wp-content/uploads/2025/11/A8_7.png 1853w" sizes="(max-width: 1024px) 100vw, 1024px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Następnie należy utworzyć połączenie Profinet „przeciągając” linię pomiędzy portami urządzeń.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="923" height="431" src="https://induprogress.pl/wp-content/uploads/2025/11/A8_8.png" class="vc_single_image-img attachment-large" alt="profinet w falownikach C2000+_8" title="profinet w falownikach C2000+_8" srcset="https://induprogress.pl/wp-content/uploads/2025/11/A8_8.png 923w, https://induprogress.pl/wp-content/uploads/2025/11/A8_8-300x140.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/A8_8-768x359.png 768w, https://induprogress.pl/wp-content/uploads/2025/11/A8_8-600x280.png 600w" sizes="(max-width: 923px) 100vw, 923px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>2.5 Aby nadać adres IP karty (w tej samej podsieci co sterownik S7-1200) należy kliknąć jeden raz na nią w widoku sieci. W zakładce General&gt;PROFINET interface&gt;Ethernet adresses znajdują się ustawienia portu Ethernet.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1024" height="669" src="https://induprogress.pl/wp-content/uploads/2025/11/A8_9-1024x669.png" class="vc_single_image-img attachment-large" alt="profinet w falownikach C2000+_9" title="profinet w falownikach C2000+_9" srcset="https://induprogress.pl/wp-content/uploads/2025/11/A8_9-1024x669.png 1024w, https://induprogress.pl/wp-content/uploads/2025/11/A8_9-300x196.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/A8_9-768x502.png 768w, https://induprogress.pl/wp-content/uploads/2025/11/A8_9-420x275.png 420w, https://induprogress.pl/wp-content/uploads/2025/11/A8_9-600x392.png 600w, https://induprogress.pl/wp-content/uploads/2025/11/A8_9.png 1247w" sizes="(max-width: 1024px) 100vw, 1024px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>2.6 Mapowanie adresów karty Profinet na sterownik S7-1200.</p>
<p>W tym celu należy dwukrotnie kliknąć na symbol karty w widoku sieci. W zakładce Device overview należy klinkąć na pozycje IN/OUT_1. W zakładce General &gt; I/O addresses można przypisać adresy sterownika, które biorą udział w wymianie danych.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1024" height="629" src="https://induprogress.pl/wp-content/uploads/2025/11/A8_10-1024x629.png" class="vc_single_image-img attachment-large" alt="profinet w falownikach C2000+_10" title="profinet w falownikach C2000+_10" srcset="https://induprogress.pl/wp-content/uploads/2025/11/A8_10-1024x629.png 1024w, https://induprogress.pl/wp-content/uploads/2025/11/A8_10-300x184.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/A8_10-768x472.png 768w, https://induprogress.pl/wp-content/uploads/2025/11/A8_10-600x369.png 600w, https://induprogress.pl/wp-content/uploads/2025/11/A8_10.png 1242w" sizes="(max-width: 1024px) 100vw, 1024px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Pierwsze 20 word’ów sterownika, zarówno Input jak i Output, jest zarezerwowane do odczytu i zapisu konkretnych rejestrów falownika. W przypadku komunikacji przy uzyciu rejestrów 60xxH i przykładowej konfiguracji zaprezentowana powyżej mapa rejestrów wygląda następująco:</p>
<p>&nbsp;</p>
<p>%QW256 = 6000h                      %IW256 = 6100h</p>
<p>%QW258 = 6001h                      %IW258 = 6101h</p>
<p>⁞              ⁞                                 ⁞              ⁞</p>
<p>%QW268 = 6006h                      %IW268 = 6106h</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>Tabela adresów Modbus z grupy 60xxH:</strong></p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<table width="693">
<tbody>
<tr>
<td width="51"><strong>Adres</strong></td>
<td width="58"><strong>RO/RW</strong></td>
<td width="51"><strong>bit</strong></td>
<td width="61"><strong>Warto</strong><strong>ść</strong></td>
<td width="82"><strong>Nazwa bitu</strong></td>
<td width="66"><strong>Priorytet</strong></td>
<td width="115"><strong>Tryb pr</strong><strong>ę</strong><strong>dko</strong><strong>ś</strong><strong>ciowy</strong></td>
<td width="106"><strong>Tryb pozycyjny</strong></td>
<td width="103"><strong>Bazowanie</strong></td>
</tr>
<tr>
<td rowspan="24" width="51">6000h</td>
<td rowspan="24" width="58">RW</td>
<td rowspan="4" width="51">0</td>
<td width="61">0</td>
<td rowspan="4" width="82"><strong>CMD_ACT</strong></td>
<td rowspan="4" width="66"><strong>4</strong></td>
<td width="115">fcmd =0</td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td width="61">0 -&gt; 1</td>
<td width="115"><strong> </strong></td>
<td width="106">POScmd = POSset</td>
<td width="103">Execute Home once</td>
</tr>
<tr>
<td width="61">1</td>
<td width="115">fcmd = Fset(Fpid)</td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td width="61">0 -&gt; 1</td>
<td width="115"><strong> </strong></td>
<td width="106"><strong> </strong></td>
<td width="103"></td>
</tr>
<tr>
<td rowspan="2" width="51">1</td>
<td width="61">0</td>
<td rowspan="2" width="82"><strong>DIR_CMD</strong></td>
<td rowspan="2" width="66"><strong>4</strong></td>
<td width="115">FWD</td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td width="61">1</td>
<td width="115">REV</td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td rowspan="2" width="51">2</td>
<td width="61">0</td>
<td rowspan="2" width="82"><strong>EXT_CMD1</strong></td>
<td rowspan="2" width="66"><strong>4</strong></td>
<td width="115"></td>
<td width="106">Resolution</td>
<td width="103"></td>
</tr>
<tr>
<td width="61">1</td>
<td width="115"></td>
<td width="106">Absolution</td>
<td width="103"></td>
</tr>
<tr>
<td rowspan="2" width="51">3</td>
<td width="61">0</td>
<td rowspan="2" width="82"><strong>HALT</strong></td>
<td rowspan="2" width="66"><strong>3</strong></td>
<td width="115"></td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td width="61">1</td>
<td width="115">Slow down to 0</td>
<td width="106">Slow down to 0</td>
<td width="103">Slow down to 0</td>
</tr>
<tr>
<td rowspan="2" width="51">4</td>
<td width="61">0</td>
<td rowspan="2" width="82"><strong>LOCK</strong></td>
<td rowspan="2" width="66"><strong>4</strong></td>
<td width="115">Unlock</td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td width="61">1</td>
<td width="115">Lock in current speed</td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td rowspan="3" width="51">5</td>
<td width="61">0</td>
<td rowspan="3" width="82"><strong>JOG</strong></td>
<td rowspan="3" width="66"><strong>4</strong></td>
<td width="115">JOG OFF</td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td width="61">1</td>
<td width="115"><strong> </strong></td>
<td width="106"><strong> </strong></td>
<td width="103"><strong> </strong></td>
</tr>
<tr>
<td width="61">0 -&gt; 1</td>
<td width="115">JOG RUN</td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td rowspan="2" width="51">6</td>
<td width="61">0</td>
<td rowspan="2" width="82"><strong>QSTOP</strong></td>
<td rowspan="2" width="66"><strong>2</strong></td>
<td width="115"></td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td width="61">1</td>
<td width="115">Quick Stop</td>
<td width="106">Quick Stop</td>
<td width="103">Quick Stop</td>
</tr>
<tr>
<td rowspan="2" width="51">7</td>
<td width="61">0</td>
<td rowspan="2" width="82"><strong>SERVO_ON</strong></td>
<td rowspan="2" width="66"><strong>1</strong></td>
<td width="115">Servo OFF</td>
<td width="106">Servo OFF</td>
<td width="103">Servo OFF</td>
</tr>
<tr>
<td width="61">1</td>
<td width="115">Servo ON</td>
<td width="106">Servo ON</td>
<td width="103">Servo ON</td>
</tr>
<tr>
<td rowspan="2" width="51">8</td>
<td width="61">0</td>
<td rowspan="2" width="82"><strong>EXT_CMD2</strong></td>
<td rowspan="2" width="66"><strong>4</strong></td>
<td width="115"></td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td width="61">1</td>
<td width="115"></td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td width="51">9</td>
<td width="61">0 -&gt; 1</td>
<td width="82"><strong> </strong></td>
<td width="66"><strong>4</strong></td>
<td width="115">Reset Position</td>
<td width="106">Reset Position</td>
<td width="103">Reset Position</td>
</tr>
<tr>
<td width="51">11~14</td>
<td colspan="6" width="533">Reserved</td>
</tr>
<tr>
<td width="51">15</td>
<td width="61">0 -&gt; 1</td>
<td width="82"><strong>RST</strong></td>
<td width="66"><strong>1</strong></td>
<td width="115">Reset</td>
<td width="106">Reset</td>
<td width="103">Reset</td>
</tr>
<tr>
<td width="51">6001h</td>
<td width="58">RW</td>
<td width="51"></td>
<td width="61"></td>
<td width="82"><strong>Mode Cmd</strong></td>
<td width="66"><strong> </strong></td>
<td width="115">0: Speed mode</td>
<td width="106">1: P2P</td>
<td width="103">3: Home</td>
</tr>
<tr>
<td width="51">6002h</td>
<td width="58">RW</td>
<td width="51"></td>
<td width="61"></td>
<td width="82"><strong>Speed Cmd</strong></td>
<td width="66"><strong> </strong></td>
<td width="115">Speed command(U16)</td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td width="51">6003h</td>
<td width="58">RW</td>
<td width="51"></td>
<td width="61"></td>
<td width="82"><strong>Torq Limit</strong></td>
<td width="66"><strong> </strong></td>
<td width="115">Torque limit(U16)</td>
<td width="106"></td>
<td width="103"></td>
</tr>
<tr>
<td width="51">6004h</td>
<td width="58">RW</td>
<td width="51"></td>
<td width="61"></td>
<td rowspan="2" width="82"><strong>Pos Cmd</strong></td>
<td rowspan="2" width="66"><strong> </strong></td>
<td width="115"><strong> </strong></td>
<td rowspan="2" width="106">Position command(S32)</td>
<td width="103"></td>
</tr>
<tr>
<td width="51">6005h</td>
<td width="58">RW</td>
<td width="51"></td>
<td width="61"></td>
<td width="115"><strong> </strong></td>
<td width="103"></td>
</tr>
<tr>
<td width="51">6006h</td>
<td width="58">RW</td>
<td width="51"></td>
<td width="61"></td>
<td><strong>Torq Cmd</strong></td>
<td><strong> </strong></td>
<td width="115"><strong> </strong></td>
<td></td>
<td width="103">Torque command(S16)</td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>Tabela adresów Modbus z grupy 61xxH:</strong></p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<table width="645">
<tbody>
<tr>
<td width="57"><strong>Adres</strong></td>
<td width="55"><strong>RO/RW</strong></td>
<td width="55"><strong>bit</strong></td>
<td width="64"><strong>Warto</strong><strong>ść</strong></td>
<td width="84"><strong>Nazwa bitu</strong></td>
<td width="133"><strong>Tryb pr</strong><strong>ę</strong><strong>dko</strong><strong>ś</strong><strong>ciowy</strong></td>
<td width="99"><strong>Tryb pozycyjny</strong></td>
<td width="99"><strong>Bazowanie</strong></td>
</tr>
<tr>
<td rowspan="17" width="57">6100h</td>
<td rowspan="17" width="55">RO</td>
<td rowspan="2" width="55">0</td>
<td width="64">0</td>
<td rowspan="2" width="84"><strong>ARRIVE</strong></td>
<td width="133">Not yet</td>
<td width="99">Not yet</td>
<td width="99">Not yet</td>
</tr>
<tr>
<td width="64">1</td>
<td width="133">Arrive target speed</td>
<td width="99">Arrive target position</td>
<td width="99">Home completed</td>
</tr>
<tr>
<td rowspan="2" width="55">1</td>
<td width="64">0</td>
<td rowspan="2" width="84"><strong>DIR</strong></td>
<td width="133">FWD</td>
<td width="99">FWD</td>
<td width="99">FWD</td>
</tr>
<tr>
<td width="64">1</td>
<td width="133">REV</td>
<td width="99">REV</td>
<td width="99">REV</td>
</tr>
<tr>
<td rowspan="2" width="55">2</td>
<td width="64">0</td>
<td rowspan="2" width="84"><strong>WARN</strong></td>
<td width="133">No Warn</td>
<td width="99">No Warn</td>
<td width="99">No Warn</td>
</tr>
<tr>
<td width="64">1</td>
<td width="133">Warn</td>
<td width="99">Warn</td>
<td width="99">Warn</td>
</tr>
<tr>
<td rowspan="2" width="55">3</td>
<td width="64">0</td>
<td rowspan="2" width="84"><strong>ERROR</strong></td>
<td width="133">No Error</td>
<td width="99">No Error</td>
<td width="99">No Error</td>
</tr>
<tr>
<td width="64">1</td>
<td width="133">Error</td>
<td width="99">Error</td>
<td width="99">Error</td>
</tr>
<tr>
<td rowspan="2" width="55">5</td>
<td width="64">0</td>
<td rowspan="2" width="84"><strong>JOG</strong></td>
<td width="133">None</td>
<td width="99">None</td>
<td width="99">None</td>
</tr>
<tr>
<td width="64">1</td>
<td width="133">On JOG</td>
<td width="99">On JOG</td>
<td width="99">On JOG</td>
</tr>
<tr>
<td rowspan="2" width="55">6</td>
<td width="64">0</td>
<td rowspan="2" width="84"><strong>QSTOP</strong></td>
<td width="133">None</td>
<td width="99">None</td>
<td width="99">None</td>
</tr>
<tr>
<td width="64">1</td>
<td width="133">On Quick Stop</td>
<td width="99">On Quick Stop</td>
<td width="99">On Quick Stop</td>
</tr>
<tr>
<td rowspan="2" width="55">7</td>
<td width="64">0</td>
<td rowspan="2" width="84"><strong>SERVO_ON</strong></td>
<td width="133">PWM OFF</td>
<td width="99">PWM OFF</td>
<td width="99">PWM OFF</td>
</tr>
<tr>
<td width="64">1</td>
<td width="133">PWM ON</td>
<td width="99">PWM ON</td>
<td width="99">PWM ON</td>
</tr>
<tr>
<td rowspan="2" width="55">8</td>
<td width="64">0</td>
<td rowspan="2" width="84"><strong>POS_Match</strong></td>
<td width="133">Not match the zero position</td>
<td width="99">Not match the zero position</td>
<td width="99">Not match the zero position</td>
</tr>
<tr>
<td width="64">1</td>
<td width="133">Match</td>
<td width="99">Match</td>
<td width="99">Match</td>
</tr>
<tr>
<td width="55">14~15</td>
<td width="64"></td>
<td width="84"><strong> </strong></td>
<td width="133"></td>
<td width="99"></td>
<td width="99"></td>
</tr>
<tr>
<td width="57">6101h</td>
<td width="55">RO</td>
<td width="55"></td>
<td width="64"><span style="text-decoration: line-through;"> </span></td>
<td width="84"><strong>Mode Cmd</strong></td>
<td width="133"><strong>Velocity(0)</strong></td>
<td width="99"><strong>Profile Position(1)</strong></td>
<td width="99"><strong>Home(3)</strong></td>
</tr>
<tr>
<td width="57">6102h</td>
<td width="55">RO</td>
<td width="55"></td>
<td width="64"></td>
<td width="84"><strong>Velocity cmd</strong></td>
<td width="133">Current speed</td>
<td width="99">Current speed</td>
<td width="99">Current speed</td>
</tr>
<tr>
<td width="57">6103h</td>
<td width="55">RO</td>
<td width="55"></td>
<td width="64"><span style="text-decoration: line-through;"> </span></td>
<td width="84"><strong> </strong></td>
<td width="133"></td>
<td width="99"></td>
<td width="99"></td>
</tr>
<tr>
<td width="57">6104h</td>
<td width="55">RO</td>
<td width="55"></td>
<td width="64"></td>
<td rowspan="2" width="84"><strong>Pos Cmd</strong></td>
<td rowspan="2" width="133">Current position</td>
<td rowspan="2" width="99">Current position</td>
<td rowspan="2" width="99">Current position</td>
</tr>
<tr>
<td width="57">6105h</td>
<td width="55">RO</td>
<td width="55"></td>
<td width="64"></td>
</tr>
<tr>
<td width="57">6106h</td>
<td width="55">RO</td>
<td width="55"></td>
<td width="64"></td>
<td width="84"><strong>Torq Cmd</strong></td>
<td width="133">Current Torque</td>
<td width="99">Current Torque</td>
<td width="99">Current Torque</td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>2.7 W celu podglądu zmiennych tworzymy nowe okno w Watch and force tables:</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="444" height="751" src="https://induprogress.pl/wp-content/uploads/2025/11/A8_11.png" class="vc_single_image-img attachment-large" alt="profinet w falownikach C2000+_11" title="profinet w falownikach C2000+_11" srcset="https://induprogress.pl/wp-content/uploads/2025/11/A8_11.png 444w, https://induprogress.pl/wp-content/uploads/2025/11/A8_11-177x300.png 177w" sizes="(max-width: 444px) 100vw, 444px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Przykład poprawnie wykonanej konfiguracji karty i falownika:</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="794" height="312" src="https://induprogress.pl/wp-content/uploads/2025/11/A8_12.png" class="vc_single_image-img attachment-large" alt="profinet w falownikach C2000+_12" title="profinet w falownikach C2000+_12" srcset="https://induprogress.pl/wp-content/uploads/2025/11/A8_12.png 794w, https://induprogress.pl/wp-content/uploads/2025/11/A8_12-300x118.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/A8_12-768x302.png 768w, https://induprogress.pl/wp-content/uploads/2025/11/A8_12-600x236.png 600w" sizes="(max-width: 794px) 100vw, 794px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>2.8 Konfigurację należy wgrać wraz z programem do sterownika.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="800" height="685" src="https://induprogress.pl/wp-content/uploads/2025/11/A8_13.png" class="vc_single_image-img attachment-large" alt="profinet w falownikach C2000+_13" title="profinet w falownikach C2000+_13" srcset="https://induprogress.pl/wp-content/uploads/2025/11/A8_13.png 800w, https://induprogress.pl/wp-content/uploads/2025/11/A8_13-300x257.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/A8_13-768x658.png 768w, https://induprogress.pl/wp-content/uploads/2025/11/A8_13-600x514.png 600w" sizes="(max-width: 800px) 100vw, 800px" /></div>
		</figure>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">3. Tryby sterowania</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>3.1 Tryb prędkościowy</p>
<p>&nbsp;</p>
<p>W celu uruchomienia falownika w trybie prędkościowym należy:</p>
<p>&#8211; ustawić parametr 00-10 – na 0 (tu wybieramy tryb sterowania, możemy również zrobić to po komunikacji wpisując 0 do adresu 6001h)</p>
<p>&#8211; wprowadzić parametry silnika:</p>
<p>&#8211; 01-00 – maksymalna częstotliwość zadana</p>
<p>&#8211; 01-01 – częstotliwość znamionowa silnika</p>
<p>&#8211; 01-02 – napięcie znamionowe silnika</p>
<p>&nbsp;</p>
<p>Następnie w celu wyzwolenia przejazdu w trybie prędkościowym:</p>
<p>&#8211; do rejestru 6002h wpisujemy zadaną częstotliwość (np. wartość 5000 odpowiada 50,00Hz)</p>
<p>&#8211; aby wywołać komendę RUN do rejestru 6000h wpisujemy 129</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>3.2 Tryb momentowy</p>
<p>&nbsp;</p>
<p>W celu uruchomienia falownika w trybie momentowym konieczne jest wybranie sterowania wektorowego oraz przeprowadzenie autotuningu silnika. W tym celu należy:</p>
<p>3.2.1 Wprowadzić parametry silnika</p>
<p>01-00 – maksymalna częstotliwość zadana</p>
<p>01-01– częstotliwość znamionowa silnika</p>
<p>01-02– napięcie znamionowe silnika</p>
<p><strong>Dla silników IM:</strong></p>
<p>05-01 – prąd znamionowy silnika</p>
<p>05-02 – moc znamionowa silnika</p>
<p>05-03 – znamionowa prędkość obrotowa silnika</p>
<p>05-04 – ilość biegunów silnika (uwaga: ilość biegunów, a nie par biegunów)</p>
<p><strong>Dla silników PM:</strong></p>
<p>05-33 – wybór rodzaju silnika (0-silnik IM, 1-silnik PM, 2 – silnik IPM)</p>
<p>05-34 – prąd znamionowy silnika</p>
<p>05-35 – moc znamionowa silnika</p>
<p>05-36 – znamionowa prędkość obrotowa</p>
<p>05-37 – ilość pól biegunów</p>
<p>05-38 – inercja silnika</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>3.2.2 Wybranie trybu autotuningu</p>
<p>Za tryb autotuningu odpowiada parametr 05-00:</p>
<p><strong>05-00 = 1 </strong>– Autotuning dynamiczny dla silników IM. Silnik zakręci się w trakcie tuningu. <strong>Przed testem należy upewnić się, że silnik nie jest podłączony do żadnego obciążenia. </strong></p>
<p><strong>05-00 = 2 </strong>– Autotuning statyczny dla silników IM. Silnik nie zakręci się w trakcie tuningu. Silnik może być podłączony do obciążenia. Użytkownik powinien ustawić wartość prądu silnika bez obciążenia – parametr <strong>05-05</strong>.</p>
<p><strong>05-00 = 5 </strong>– Autotuning dynamiczny dla silników PM</p>
<p><strong>05</strong>&#8211;<strong>00 = 13 </strong>– Autotuning statyczny dla silników PM</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>3.2.3 Po ustawieniu parametru 05-00 możemy załączyć autotuning naciskając przycisk RUN.</p>
<p>Jeżeli autotuning zakończy się poprawnie, to należy sprawdzić czy pojawiły się wartości w parametrach 05-05…05-09 dla silników IM lub w parametrach 05-39…05-43 dla silników IM.</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>3.2.4 Ustawienie parametrów enkodera</p>
<p>Po wykonaniu autotuningu możemy przejść do konfiguracji enkodera. W falownikach serii C2000+ koniecznie jest dołożenie dodatkowej karty rozszerzeń, aby można było podłączyć enkoder</p>
<p>&nbsp;</p>
<p>10-00 – typ enkodera</p>
<p>10-01 – liczba impulsów na obrót</p>
<p>10-02 – tryb pracy enkodera</p>
<p>&nbsp;</p>
<p>Kolejnym krokiem będzie ustawienie trybu momentowego na falowniku. W tym celu należy:</p>
<p>&#8211; 00-10 – na 2 (tu wybieramy tryb sterowania, możemy również zrobić to po komunikacji wpisując 2 do adresu 6001h)</p>
<p>&#8211; 00-11 – tryb pracy w zależności od silnika (4 – tryb wektorowy dla silnika PM z enkoderem, 3 &#8211; tryb wektorowy dla silnika IM z enkoderem, 5 – tryb wektorowy bezczujnikowy dla silnika IM)</p>
<p>&#8211; 00-13 – wybór trybu momentowego (0 – dla silnika IM + enkoder, 1 – dla silnika PM + enkoder, 2 – dla silnika IM bezczujnikowego)</p>
<p>&#8211; 11-33 – na 5 (źródło momentu zadanego – karta komunikacyjna Profinet)</p>
<p>&#8211; 11-34 – do tego parametru będziemy wysyłać wartość momentu zadanego</p>
<p>&#8211; 11-36 – na 2 (ograniczenie prędkości z komendy częstotliwości, którą będziemy ustawiać komunikacyjnie po Profinet)</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>Następnie w celu wyzwolenia przejazdu w trybie momentowym:</p>
<p>&#8211; do rejestru 6002h wpisujemy wartość ograniczenia prędkości w trybie momentowym (np. wartość 5000 odpowiada 50,00 Hz)</p>
<p>&#8211; do rejestru 6006h wpisujemy wartość momentu zadanego (np. wpisana wartość 100 odpowiada 10.0% wartości momentu nominalnego)</p>
<p>&#8211; aby wywołać komendę RUN do rejestru 6000h wpisujemy 128</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>3.3 Tryb pozycyjny</p>
<p>&nbsp;</p>
<p>W celu uruchomienia trybu pozycyjnego na falowniku C2000+ konieczne będzie podobnie jak w przypadku trybu momentowego wybranie sterowania wektorowego oraz przeprowadzenie autotuningu silnika i ustawienie parametrów enkodera. W tym celu należy powtórzyć punkty 1-4 z rozdziału 3.2.</p>
<p>&nbsp;</p>
<p>Po wykonaniu autotuningu oraz ustawieniu parametrów enkodera należy przejść do ustawień trybu pozycyjnego na falowniku:</p>
<p>&#8211; 00-10 na 1 (tu wybieramy tryb sterowania, możemy również zrobić to po komunikacji wpisując 2 do adresu 6001h)</p>
<p>&#8211; 00-11 tryb pracy w zależności od silnika (3- tryb wektorowy dla silnika PM z enkoderem,    3 – tryb wektorowy dla silnika IM z enkoderem)</p>
<p>&#8211; 00-12 – wybór trybu pozycyjnego (0 – przejazd inkrementalny, 1 – przejazd absolutny)</p>
<p>&#8211; 11-40 – na 5 (źródło komendy pozycji – karta komunikacyjna Profinet)</p>
<p>&#8211; 11-43 – maksymalna częstotliwość zadana w trybie pozycyjnym</p>
<p>&#8211; 11-44 – rampa przyspieszania w trybie pozycyjnym</p>
<p>&#8211; 11-45 – rampa hamowania w trybie pozycyjnym</p>
<p>&#8211; 11-68 – wybór metody homingu</p>
<p>&#8211; 11-70 i 11-71 – prędkości homingu, pierwsza definiuje przejazd do czujnika bądź krańcówki, druga dotyczy ruchu po wykryciu zbocza czujnika bądź krańcówki</p>
<p>&#8211; 11-72 – czas przyspieszenia/hamowania dla homingu</p>
<p>&nbsp;</p>
<p>W celu wyzwolenia przejazdu w trybie pozycyjnym:</p>
<p>&#8211; do rejestrów 6004h i 6005h należy wpisać pozycję zadaną  wyrażoną 32-bitowo</p>
<p>&#8211; aby wywołać komendę RUN do rejestru 6000h wpisujemy 129</p>
<p>&nbsp;</p>
<p>Wykonanie procedury homingu:</p>
<p>&nbsp;</p>
<p>Aby wykonać homing, należy ustawić parametry wymienione i opisane wcześniej, czyli:    11-68, 11-70, 11-71, 11-72.</p>
<p>W dalszej kolejności należy przypisać czujnik bazowania, bądź też krańcówki do wybranych wejść cyfrowych falownika.</p>
<p>Następnie należy:</p>
<p>&#8211; do rejestru 6001h wpisać 3 (ustawienie trybu homingu)</p>
<p>&#8211; wyzwolić homing wpisując do rejestru 6000h wartość 129</p>
<p>&nbsp;</p>
<p>W zależności od wybranej funkcji homingu w parametrze 11-68 napęd wykona bazowanie. Po poprawnym wykonaniu procedury homingu pozycja aktualna na falowniku powinna wynosić 0.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><em>Opublikowano: 22 października 2024</em></p>

		</div>
	</div>
</div></div></div></div>
</div><p>Artykuł <a href="https://induprogress.pl/artykuly-techniczne/jak-skonfigurowac-profinet-w-falownikach-serii-c2000/">Jak skonfigurować Profinet w falownikach serii C2000+</a> pochodzi z serwisu <a href="https://induprogress.pl">Induprogress</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://induprogress.pl/artykuly-techniczne/jak-skonfigurowac-profinet-w-falownikach-serii-c2000/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>