<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Archiwa DOP100 - Induprogress</title>
	<atom:link href="https://induprogress.pl/tag/dop100/feed/" rel="self" type="application/rss+xml" />
	<link>https://induprogress.pl/tag/dop100/</link>
	<description></description>
	<lastBuildDate>Thu, 02 Apr 2026 06:09:02 +0000</lastBuildDate>
	<language>pl-PL</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://induprogress.pl/wp-content/uploads/2024/10/fav-100x100.png</url>
	<title>Archiwa DOP100 - Induprogress</title>
	<link>https://induprogress.pl/tag/dop100/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Konfiguracja zdalnego dostępu do HMI DOP-100 przez DIACloud z wykorzystaniem modułu Wi-Fi DX-MWB-01</title>
		<link>https://induprogress.pl/artykuly-techniczne/konfiguracja-zdalnego-dostepu-do-hmi-dop-100/</link>
					<comments>https://induprogress.pl/artykuly-techniczne/konfiguracja-zdalnego-dostepu-do-hmi-dop-100/#respond</comments>
		
		<dc:creator><![CDATA[Aleksandra Puzon]]></dc:creator>
		<pubDate>Wed, 01 Apr 2026 12:59:28 +0000</pubDate>
				<category><![CDATA[Artykuły techniczne]]></category>
		<category><![CDATA[Sterowanie i wizualizacja procesów]]></category>
		<category><![CDATA[DIACloud]]></category>
		<category><![CDATA[DOP100]]></category>
		<category><![CDATA[HMI]]></category>
		<guid isPermaLink="false">https://induprogress.pl/?p=40354</guid>

					<description><![CDATA[<p>Podstawowa konfiguracja połączenia zdalnego do HMI DOP-100</p>
<p>Artykuł <a href="https://induprogress.pl/artykuly-techniczne/konfiguracja-zdalnego-dostepu-do-hmi-dop-100/">Konfiguracja zdalnego dostępu do HMI DOP-100 przez DIACloud z wykorzystaniem modułu Wi-Fi DX-MWB-01</a> pochodzi z serwisu <a href="https://induprogress.pl">Induprogress</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" class="vc_single_image-img " src="https://induprogress.pl/wp-content/uploads/2024/11/artykuly-techniczne-banner.jpg" width="1080" height="280" alt="artykuły techniczne induprogress" title="artykuły techniczne banner" loading="lazy" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Jakie informacje znajdziesz w artykule</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Opracowanie przedstawia podstawową konfigurację połączenia zdalnego do <a href="https://induprogress.pl/kategoria-produktu/sterowanie-i-wizualizacja-procesow/graficzne-panele-operatorskie-hmi/seria-dop-100/">HMI DOP-100</a> wyposażonego w moduł Wi-Fi DX-MWB-01 przez chmurę DIACloud. W opracowaniu pokazano w jaki sposób:</p>
<ul>
<li>podłączyć DOP-100 do Internetu przez Wi-Fi,</li>
<li>podłączyć HMI do konta w nowej chmurze DIACloud,</li>
<li>uzyskać zdalny podgląd HMI przez VNC w z poziomu aplikacji mobilnej lub przeglądarki,</li>
<li>konfigurować eComm Bypass w celu zdalnego wgrywania programu na PLC poprzez tunel w DIACom i panel DOP100 z modułem DX-MWB-01.</li>
</ul>

		</div>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Wymagany Software do konfiguracji zdalnego dostępu:</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li>Dia Screen 1.6.2 lub wyższa</li>
<li>Aplikacja mobilna eDIAcloud</li>
<li>DIACom 1.5.0.4 lub wyższa</li>
<li>COMMGR 2.11 lub wyższa</li>
<li>ISPSoft</li>
</ul>

		</div>
	</div>
<h2 style="text-align: left" class="vc_custom_heading">Wymagany Hardware:</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li><strong>DX-MWB-01</strong> – moduł Wi-Fi z anteną</li>
</ul>

		</div>
	</div>
<h2 style="text-align: left" class="vc_custom_heading">Wymagane Licencje:</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li>Start-Up (Darmowa licencja początkowa) – Dostępna na 1. rok użytkowania karty DX-MWB-01. Transfer: 12GB, Okres ważności: 1 rok</li>
<li>Remote Access (Licencja na zdalny dostęp)
<ul>
<li>DX-TRA-9912 &#8211; Transfer: 12 GB / rok, Okres ważności: Bezterminowa</li>
<li>DX-TRA-0036 &#8211; Transfer: 36 GB, Okres ważności: 1 rok</li>
</ul>
</li>
</ul>

		</div>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>1. Podłączenie panelu DOP-100 do Internetu</strong></p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>1.1.</strong> W celu poszerzenia funkcjonalności panelu DOP-100 o komunikację przez Wi-Fi podłączamy adapter DX-MWB-01 za pośrednictwem złącza USB z tyłu panelu. Aby umożliwić połączenie z aplikacją chmurową konieczne może okazać się wgranie aktualnego firmware’u na HMI (Project -&gt; Update Firmware w DIAScreen).</p>
<p><strong>1.2.</strong> Z poziomu menu systemowego przechodzimy do zakładki Network. W oknie Wi-Fi wybieramy opcję Enable: ON i łączymy się z wybraną siecią Wi-Fi</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="628" height="472" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC" title="DOP100_Zdalny dostep do HMI i PLC" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC.jpeg 628w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC-300x225.jpeg 300w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC-600x451.jpeg 600w" sizes="(max-width: 628px) 100vw, 628px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>1.3.</strong> Pozostając w menu systemowym przechodzimy do zakładki DIACloud, a następnie w oknie Device Info wybieramy opcję Cloud Service: ON.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="633" height="472" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_2.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_2" title="DOP100_Zdalny dostep do HMI i PLC_2" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_2.jpeg 633w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_2-300x224.jpeg 300w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_2-600x447.jpeg 600w" sizes="(max-width: 633px) 100vw, 633px" /></div>
		</figure>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>2. Zdalny dostęp do HMI z poziomu aplikacji mobilnej.</strong></p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>2.1.</strong> Ze Sklepu Play/App Store pobieramy aplikację eDIACloud i zakładamy na niej konto. Następnie przechodzimy do zakładki Devices i wybieramy opcję dodania nowego urządzenia poprzez skan kodu QR.</p>
<p><strong>2.2.</strong> Skanujemy kod, który znajduje się na obudowie adaptera DX-MWB-01 i wprowadzamy PIN, który również zapisany jest na adapterze.</p>

		</div>
	</div>
<div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="414" height="909" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_3.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_3" title="DOP100_Zdalny dostep do HMI i PLC_3" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_3.jpeg 414w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_3-137x300.jpeg 137w" sizes="(max-width: 414px) 100vw, 414px" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="417" height="933" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_4.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_4" title="DOP100_Zdalny dostep do HMI i PLC_4" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_4.jpeg 417w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_4-134x300.jpeg 134w" sizes="(max-width: 417px) 100vw, 417px" /></div>
		</figure>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>2.3.</strong> W kolejnym kroku aplikacja poprosi o zeskanowanie kodu QR panelu HMI. W tym celu w menu systemowym panelu przechodzimy do zakładki DIACloud -&gt; Binding HMI. Po zeskanowaniu wyświetlanego na panelu kodu, konfigurujemy Bind Device nadając mu nazwę i grupę urządzeń.</p>

		</div>
	</div>
<div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="631" height="473" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_5.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_5" title="DOP100_Zdalny dostep do HMI i PLC_5" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_5.jpeg 631w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_5-300x225.jpeg 300w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_5-600x450.jpeg 600w" sizes="(max-width: 631px) 100vw, 631px" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="463" height="1024" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_6-463x1024.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_6" title="DOP100_Zdalny dostep do HMI i PLC_6" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_6-463x1024.jpeg 463w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_6-136x300.jpeg 136w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_6.jpeg 496w" sizes="(max-width: 463px) 100vw, 463px" /></div>
		</figure>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>2.4.</strong> Po dodaniu urządzenia do aplikacji możemy połączyć się z nim zdalnie. W aplikacji wybieramy HMI z listy urządzeń i przechodzimy do zakładki HMI Screen. Przed połączeniem należy upewnić się, że panel ma włączoną opcję VNC (System Menu -&gt; Network App -&gt; VNC -&gt; Enable : ON).</p>

		</div>
	</div>
<div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="460" height="1024" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_7-460x1024.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_7" title="DOP100_Zdalny dostep do HMI i PLC_7" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_7-460x1024.jpeg 460w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_7-135x300.jpeg 135w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_7.jpeg 526w" sizes="(max-width: 460px) 100vw, 460px" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="459" height="1024" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_8-459x1024.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_8" title="DOP100_Zdalny dostep do HMI i PLC_8" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_8-459x1024.jpeg 459w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_8-135x300.jpeg 135w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_8.jpeg 528w" sizes="(max-width: 459px) 100vw, 459px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>3. Zdalny dostęp do HMI z poziomu przeglądarki</strong></p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>3.1.</strong> Otwieramy stronę <a href="https://hms.diacloudsolutions.com/#/login">https://hms.diacloudsolutions.com</a> i logujemy się na to samo konto co na aplikacji mobilnej.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1024" height="459" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_9-1024x459.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_9" title="DOP100_Zdalny dostep do HMI i PLC_9" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_9-1024x459.jpeg 1024w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_9-300x134.jpeg 300w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_9-768x344.jpeg 768w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_9-600x269.jpeg 600w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_9.jpeg 1372w" sizes="(max-width: 1024px) 100vw, 1024px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>3.2.</strong> W zakładce Device List powinien być dostępny wcześniej dodany panel HMI. Aby połączyć się z urządzeniem przez VNC wybieramy Dashboard -&gt; HMI Screen.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1024" height="459" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_10-1024x459.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_10" title="DOP100_Zdalny dostep do HMI i PLC_10" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_10-1024x459.jpeg 1024w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_10-300x134.jpeg 300w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_10-768x344.jpeg 768w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_10-600x269.jpeg 600w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_10.jpeg 1361w" sizes="(max-width: 1024px) 100vw, 1024px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>4. Konfiguracja zdalnego dostępu do PLC poprzez tunel DIACom</strong></p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>4.1.</strong> W celu utworzenia tunelu pobieramy aplikację DIACom, a następnie logujemy się danymi uprzednio utworzonego konta w portalu hms.diacloudsolutions.com.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="463" height="340" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_11.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_11" title="DOP100_Zdalny dostep do HMI i PLC_11" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_11.jpeg 463w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_11-300x220.jpeg 300w" sizes="(max-width: 463px) 100vw, 463px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>4.2.</strong> W następnym kroku wybieramy opcję HMS dostępną w lewym górnym rogu okna programu.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="895" height="593" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_12.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_12" title="DOP100_Zdalny dostep do HMI i PLC_12" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_12.jpeg 895w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_12-300x199.jpeg 300w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_12-768x509.jpeg 768w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_12-600x398.jpeg 600w" sizes="(max-width: 895px) 100vw, 895px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>4.3.</strong> Po lewej stronie okna programu wybieramy urządzenie podpięte wcześniej do konta DIACloud, a następnie klikamy Create Tunnel.</p>
<p><strong>4.4.</strong> Gdy połączenie zostanie nawiązane otrzymamy komunikat Tunnel is active. W prawym dolnym rogu okna programu zobaczymy dodatkowy lokalny adres IP przydzielony dla komputera. Urządzeniu HMI zawsze przydzielony zostanie adres 192.168.160.100 – dodatkowy adres IP wykorzystywany dla połączenia za pośrednictwem tunelu, inny niż adres IP skonfigurowany w Network Settings panelu.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="899" height="594" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_13.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_13" title="DOP100_Zdalny dostep do HMI i PLC_13" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_13.jpeg 899w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_13-300x198.jpeg 300w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_13-768x507.jpeg 768w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_13-600x396.jpeg 600w" sizes="(max-width: 899px) 100vw, 899px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>4.5.</strong> Adres IP wirtualnej karty sieciowej komputera ustawiamy w tej samej podsieci co HMI &#8211; 192.168.160.X.</p>
<p><strong>4.6.</strong> W ustawieniach DIACom dostępna jest opcja wybrania domyślnego serwera. W przypadku problemów z nawiązaniem połączenia należy wybrać serwer najbliższy naszej lokalizacji.</p>

		</div>
	</div>
<div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="960" height="606" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_14.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_14" title="DOP100_Zdalny dostep do HMI i PLC_14" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_14.jpeg 960w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_14-300x189.jpeg 300w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_14-768x485.jpeg 768w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_14-600x379.jpeg 600w" sizes="(max-width: 960px) 100vw, 960px" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="569" height="438" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_15.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_15" title="DOP100_Zdalny dostep do HMI i PLC_15" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_15.jpeg 569w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_15-300x231.jpeg 300w" sizes="(max-width: 569px) 100vw, 569px" /></div>
		</figure>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>4.7.</strong> Następnie przechodzimy do aplikacji COMMGR i po lewej stronie dodajemy nowe urządzenie poprzez funkcję New Driver w lewym górnym rogu i ustawiamy mu następujące parametry:</p>
<p><strong>Device Name</strong> – „Nazwa własna”</p>
<p><strong>Type</strong> – Ethernet</p>
<p><strong>Communication Type</strong> – HMI</p>
<p><strong>Device Type</strong> – Delta</p>
<p><strong>Bypass Mode</strong> – Ethernet Bypass</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1024" height="550" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_16-1024x550.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_16" title="DOP100_Zdalny dostep do HMI i PLC_16" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_16-1024x550.jpeg 1024w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_16-300x161.jpeg 300w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_16-768x412.jpeg 768w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_16-600x322.jpeg 600w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_16.jpeg 1227w" sizes="(max-width: 1024px) 100vw, 1024px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>4.8.</strong> Po wybraniu opcji HMI w polu Connection Type zatwierdzamy komunikat:</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="392" height="152" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_17.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_17" title="DOP100_Zdalny dostep do HMI i PLC_17" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_17.jpeg 392w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_17-300x116.jpeg 300w" sizes="(max-width: 392px) 100vw, 392px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>4.9.</strong> Po zatwierdzeniu komunikatu z COMMGR powinna otworzyć się aplikacja eComm. W nowo otwartym oknie wybieramy opcję Ethernet ByPass, a następnie klikamy ikonę plusa w celu dodania nowego bypassu.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="995" height="734" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_18.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_18" title="DOP100_Zdalny dostep do HMI i PLC_18" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_18.jpeg 995w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_18-300x221.jpeg 300w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_18-768x567.jpeg 768w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_18-600x443.jpeg 600w" sizes="(max-width: 995px) 100vw, 995px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>4.10.</strong> Wybieramy kartę sieciową DIACom Ethernet Adapter, ustawiamy adres IP HMI na przydzielony wcześniej adres lokalny – 192.168.160.100 oraz adres IP użytego w konfiguracji PLC.</p>
<p><strong>4.11.</strong> Po wprowadzeniu adresów wybieramy opcję Create/Modify</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1000" height="738" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_19.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_19" title="DOP100_Zdalny dostep do HMI i PLC_19" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_19.jpeg 1000w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_19-300x221.jpeg 300w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_19-768x567.jpeg 768w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_19-600x443.jpeg 600w" sizes="(max-width: 1000px) 100vw, 1000px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>4.12.</strong> W celu uruchomienia bypassu klikamy ikonę czarnego ludzika na zielonym tle. Jeżeli wszystko zostało skonfigurowane poprawnie, ludzik powinien zmienić kolor z czarnego na szary, a w dolnej części aplikacji wyświetli się komunikat „Start ethernet bypass SUCCESS”</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1000" height="735" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_20.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_20" title="DOP100_Zdalny dostep do HMI i PLC_20" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_20.jpeg 1000w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_20-300x221.jpeg 300w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_20-768x564.jpeg 768w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_20-600x441.jpeg 600w" sizes="(max-width: 1000px) 100vw, 1000px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>4.13.</strong> Wracamy do programu COMMGR. Po prawej stronie okna programu w sekcji Ethernet Card wybieramy opcję DIACom Ethernet Adapter i zapisujemy konfigurację.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1024" height="550" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_21-1024x550.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_21" title="DOP100_Zdalny dostep do HMI i PLC_21" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_21-1024x550.jpeg 1024w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_21-300x161.jpeg 300w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_21-768x413.jpeg 768w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_21-600x322.jpeg 600w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_21.jpeg 1275w" sizes="(max-width: 1024px) 100vw, 1024px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>4.14.</strong> Przechodzimy do ISPSoft, i wybieramy utworzony wcześniej driver (Tools -&gt;<br />
Communication Settings). Dzięki temu możliwe będzie wgrywanie programu na PLC<br />
poprzez tunel DIACom.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="409" height="307" src="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_22.jpeg" class="vc_single_image-img attachment-large" alt="DOP100_Zdalny dostep do HMI i PLC_22" title="DOP100_Zdalny dostep do HMI i PLC_22" srcset="https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_22.jpeg 409w, https://induprogress.pl/wp-content/uploads/2026/04/DOP100_Zdalny-dostep-do-HMI-i-PLC_22-300x225.jpeg 300w" sizes="(max-width: 409px) 100vw, 409px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><em>Opublikowano: 1 kwietnia 2026</em></p>

		</div>
	</div>
</div></div></div></div>
</div><p>Artykuł <a href="https://induprogress.pl/artykuly-techniczne/konfiguracja-zdalnego-dostepu-do-hmi-dop-100/">Konfiguracja zdalnego dostępu do HMI DOP-100 przez DIACloud z wykorzystaniem modułu Wi-Fi DX-MWB-01</a> pochodzi z serwisu <a href="https://induprogress.pl">Induprogress</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://induprogress.pl/artykuly-techniczne/konfiguracja-zdalnego-dostepu-do-hmi-dop-100/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
