<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Archiwa history buffer - Induprogress</title>
	<atom:link href="https://induprogress.pl/tag/history-buffer/feed/" rel="self" type="application/rss+xml" />
	<link>https://induprogress.pl/tag/history-buffer/</link>
	<description></description>
	<lastBuildDate>Tue, 14 Oct 2025 06:28:28 +0000</lastBuildDate>
	<language>pl-PL</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://induprogress.pl/wp-content/uploads/2024/10/fav-100x100.png</url>
	<title>Archiwa history buffer - Induprogress</title>
	<link>https://induprogress.pl/tag/history-buffer/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Eksport danych w panelach HMI– oprogramowanie eServer cz. 2 History Buffer Setup</title>
		<link>https://induprogress.pl/artykuly-techniczne/eksport-danych-w-panelach-hmi-oprogramowanie-eserver-cz-2-history-buffer-setup/</link>
					<comments>https://induprogress.pl/artykuly-techniczne/eksport-danych-w-panelach-hmi-oprogramowanie-eserver-cz-2-history-buffer-setup/#respond</comments>
		
		<dc:creator><![CDATA[Aleksandra Puzon]]></dc:creator>
		<pubDate>Tue, 14 Oct 2025 06:27:18 +0000</pubDate>
				<category><![CDATA[Artykuły techniczne]]></category>
		<category><![CDATA[Sterowanie i wizualizacja procesów]]></category>
		<category><![CDATA[eServer]]></category>
		<category><![CDATA[history buffer]]></category>
		<category><![CDATA[HMI]]></category>
		<guid isPermaLink="false">https://induprogress.pl/?p=14185</guid>

					<description><![CDATA[<p>Oprogramowanie eServer (dedykowane do paneli HMI Delta Electronics) </p>
<p>Artykuł <a href="https://induprogress.pl/artykuly-techniczne/eksport-danych-w-panelach-hmi-oprogramowanie-eserver-cz-2-history-buffer-setup/">Eksport danych w panelach HMI– oprogramowanie eServer cz. 2 History Buffer Setup</a> pochodzi z serwisu <a href="https://induprogress.pl">Induprogress</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" class="vc_single_image-img " src="https://induprogress.pl/wp-content/uploads/2024/11/artykuly-techniczne-banner.jpg" width="1080" height="280" alt="artykuły techniczne induprogress" title="artykuły techniczne banner" loading="lazy" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Eksport danych cz. 2 - History Buffer Setup</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Do archiwizacji danych można wykorzystać oprogramowanie eServer (<strong>Eksport Danych cz.1</strong>), które wykorzystuje port Ethernet. W przypadku paneli HMI bez wbudowanego portu Ethernet do zapisywania danych może posłużyć opcja <strong>HISTORY BUFFER SETUP</strong>, która pozwala na eksport danych w formacie CSV na zewnętrzny nośnik USB.</p>
<p>W kilku krokach opiszemy konfigurację oraz dostępne opcje w History Buffer.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="239" height="300" src="https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_1.jpg" class="vc_single_image-img attachment-medium" alt="History Buffer_1" title="History Buffer_1" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Po wybraniu HISTORY BUFFER SETUP otwiera się okienko konfiguracji i aby utworzyć bufor danych wybieramy Add (1). Następnie wyświetli się okno właściwości bufora. Przyciski (2) oraz (3) służą do usunięcia lub modyfikacji wybranego bufora.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="300" height="142" src="https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_2-300x142.jpg" class="vc_single_image-img attachment-medium" alt="History Buffer_2" title="History Buffer_2" srcset="https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_2-300x142.jpg 300w, https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_2-768x363.jpg 768w, https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_2-600x284.jpg 600w, https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_2.jpg 1024w" sizes="(max-width: 300px) 100vw, 300px" /></div>
		</figure>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="289" height="300" src="https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_3-289x300.jpg" class="vc_single_image-img attachment-medium" alt="History Buffer_3" title="History Buffer_3" srcset="https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_3-289x300.jpg 289w, https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_3.jpg 545w" sizes="(max-width: 289px) 100vw, 289px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>W miejscu <strong>(1)</strong> wybieramy adres rejestr od którego chcemy zbierać dane;<br />
<strong>(2)</strong> – ilość rejestrów które monitorujemy;<br />
<strong>(3)</strong> – ilość próbek.<br />
W <strong>(4)</strong> ustawiamy czas próbkowania (częstotliwość zbierania próbek).<br />
Zaznaczając opcję<strong> (5)</strong> automatycznie generujemy stempel czasu do zebranych danych.<br />
W <strong>(6)</strong> należy wybrać Non-volatile USB Disk (zapis danych na zewnętrznym USB).<br />
Aby archiwizować dane oraz eksportować do pliku CSV należy zaznaczyć opcję eksportu<strong> (7)</strong>. Przycisk <strong>(8)</strong> otwiera okno ustawień nazw poszczególnych kolumn oraz innych parametrów danych (rys. poniżej)</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="190" height="300" src="https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_4-190x300.jpg" class="vc_single_image-img attachment-medium" alt="History Buffer_4" title="History Buffer_4" srcset="https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_4-190x300.jpg 190w, https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_4.jpg 479w" sizes="(max-width: 190px) 100vw, 190px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Wybierając opcję <strong>(9)</strong> zapisujemy dane do jednego pliku o wybranej nazwie. Opcja <strong>(10)</strong> pozwala na zapisanie danych w kilku plikach o nazwie zmienianej dynamicznie (zależnie od czasu). Zapis danych w kolejnym pliku wyzwala <em>Saving Trigger</em> (wybrany przez nas bit, który należy załączyć w danej chwili). Ustawiając konfigurację przedstawioną na powyższym rys. zbieramy dane (1000 próbek<br />
z czasem próbkowania 1s) z rejestrów $100, $101, $102 oraz $103 do pliku CSV o nazwie TEST.</p>
<p>W zakładce <em>Title Setting</em> ustawiamy tytuł tabeli oraz ilość komórek dla niego zarezerwowanych, zaś w <em>Data field</em> możemy ustawić tytuł dla każdej kolumny danych oraz format danych.</p>
<p><strong>UWAGA!</strong></p>
<p>Zapis danych na zewnętrzny dysk USB jest wyzwalany poprzez załączenie bitu odpowiadającego za zapis bufora danych do zewnętrznego urządzenia. Aby ustawić odpowiedni bit, należy wejść w Options-&gt; Configuration-&gt; Control Block, zaznaczyć General Control oraz zarezerwować miejsce w pamięci przeznaczone dla Control Block. Przykładową konfigurację przedstawia poniższy rysunek.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="300" height="235" src="https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_5-300x235.jpg" class="vc_single_image-img attachment-medium" alt="History Buffer_5" title="History Buffer_5" srcset="https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_5-300x235.jpg 300w, https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_5-768x602.jpg 768w, https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_5-600x470.jpg 600w, https://induprogress.pl/wp-content/uploads/2025/10/History-Buffer_5.jpg 787w" sizes="(max-width: 300px) 100vw, 300px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Dla przedstawionego przypadku zapis danych na dysk USB będzie wykonany po załączeniu bitu $0.5.<br />
Wygenerowany plik znajduje się na dysku USB podpiętym do HMI w folderze HMI\HMI-000.</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><em>Opublikowano: 8 stycznia 2017</em></p>

		</div>
	</div>
</div></div></div></div>
</div><p>Artykuł <a href="https://induprogress.pl/artykuly-techniczne/eksport-danych-w-panelach-hmi-oprogramowanie-eserver-cz-2-history-buffer-setup/">Eksport danych w panelach HMI– oprogramowanie eServer cz. 2 History Buffer Setup</a> pochodzi z serwisu <a href="https://induprogress.pl">Induprogress</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://induprogress.pl/artykuly-techniczne/eksport-danych-w-panelach-hmi-oprogramowanie-eserver-cz-2-history-buffer-setup/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
