<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Archiwa SCADA - Induprogress</title>
	<atom:link href="https://induprogress.pl/tag/scada/feed/" rel="self" type="application/rss+xml" />
	<link>https://induprogress.pl/tag/scada/</link>
	<description></description>
	<lastBuildDate>Tue, 14 Oct 2025 11:33:58 +0000</lastBuildDate>
	<language>pl-PL</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://induprogress.pl/wp-content/uploads/2024/10/fav-100x100.png</url>
	<title>Archiwa SCADA - Induprogress</title>
	<link>https://induprogress.pl/tag/scada/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Integracja oprogramowania SCADA z bazami danych przez interfejs ODBC</title>
		<link>https://induprogress.pl/artykuly-techniczne/integracja-oprogramowania-scada-z-bazami-danych-przez-interfejs-odbc/</link>
					<comments>https://induprogress.pl/artykuly-techniczne/integracja-oprogramowania-scada-z-bazami-danych-przez-interfejs-odbc/#respond</comments>
		
		<dc:creator><![CDATA[Aleksandra Puzon]]></dc:creator>
		<pubDate>Tue, 14 Oct 2025 11:13:28 +0000</pubDate>
				<category><![CDATA[Artykuły techniczne]]></category>
		<category><![CDATA[Sterowanie i wizualizacja procesów]]></category>
		<category><![CDATA[ODBC]]></category>
		<category><![CDATA[SCADA]]></category>
		<category><![CDATA[WellinTech]]></category>
		<guid isPermaLink="false">https://induprogress.pl/?p=14255</guid>

					<description><![CDATA[<p>Ten artykuł opisuje sposób połączenia i wymiany danych między oprogramowaniem SCADA, a bazami danych, których producenci </p>
<p>Artykuł <a href="https://induprogress.pl/artykuly-techniczne/integracja-oprogramowania-scada-z-bazami-danych-przez-interfejs-odbc/">Integracja oprogramowania SCADA z bazami danych przez interfejs ODBC</a> pochodzi z serwisu <a href="https://induprogress.pl">Induprogress</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" class="vc_single_image-img " src="https://induprogress.pl/wp-content/uploads/2024/11/artykuly-techniczne-banner.jpg" width="1080" height="280" alt="artykuły techniczne induprogress" title="artykuły techniczne banner" loading="lazy" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Oprogramowanie SCADA od WellinTech</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Ten artykuł opisuje sposób połączenia i wymiany danych między oprogramowaniem <strong>SCADA</strong> firmy <strong>WellinTech</strong> (KingSCADA i KingView 7.0), a bazami danych, których producenci udostępniają sterownik ODBC.</p>
<p>Współczesne systemy automatyki przemysłowej ewoluują w kierunku rozproszonych sieci mniejszych systemów, które wcześniej stanowiły autonomiczne zespoły. Przykładem może być międzynarodowa korporacja posiadająca rozproszone fabryki. Pracownicy centrali chcieliby mieć dostęp do danych z produkcji poszczególnych fabryk. Także mniejsze firmy posiadają systemy zarządzania zasobami ERP, w których zapisywane są dane zleceń, które powinny być przekazywane do wykonania. Najlepiej, aby wszystkie dane były wymieniane automatycznie.</p>
<p>Oprogramowanie SCADA firmy WellinTech wpisuje się w trend integracji automatyki z zewnętrznymi systemami informatycznymi, umożliwiając wymianę danych z bazami danych (także tymi dostępnymi zdalnie, tj. na innym komputerze). Zarówno <strong>KingSCADA</strong> i <strong>KingView</strong> dysponują interfejsem <strong>ODBC</strong>, który może być wykorzystany w tym celu.</p>
<p>W artykule przedstawiono sposób połączenia z bazami danych MS Access (plik *.mdb), MySQL oraz MS SQL Server 2012 Express. Producenci wymienionych baz danych przygotowali sterowniki zgodne ze standardem ODBC. Standard ten jest implementowany przez większość producentów baz danych.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Utworzenie źródła danych DSN</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Pierwszym krokiem do uzyskania połączenia z bazą danych jest zdefiniowanie w systemie Windows źródła danych DSN (Data Source Name). KingSCADA i KingView są programami 32 bitowymi, dlatego wymagają 32 bitowego DSN.</p>
<p>Aby skonfigurować DSN należy uruchomić program [Administrator źródła danych ODBC] z lokalizacji:</p>
<p>&#8211; w przypadku systemów 64 bit:</p>
<p>%systemdrive%\Windows\SysWoW64\Odbcad32.exe</p>
<p>&#8211; w przypadku systemów 32 bit:</p>
<p>%systemdrive%\Windows\System32\Odbcad32.exe</p>
<p>Parametr %systemdrive% oznacza dysk systemowy, zazwyczaj jest to dysk C. Należy wybrać zakładkę <strong>[Systemowe DSN]</strong> i nacisnąć przycisk <strong>[Dodaj]</strong>.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="518" height="408" src="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-1.png" class="vc_single_image-img attachment-large" alt="odbc-dsn-windows-32bit-1" title="odbc-dsn-windows-32bit-1" srcset="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-1.png 518w, https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-1-300x236.png 300w" sizes="(max-width: 518px) 100vw, 518px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Po naciśnięciu przycisku wyświetlona zostanie lista dostępnych sterowników ODBC. Jeżeli na liście brakuje wymaganego sterownika, należy go zainstalować. Należy pamiętać, że sterownik musi być w wersji 32 bit.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Ustawienie DSN dla MS Access</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Z listy dostępnych sterowników należy wybrać sterownik obsługujący pliki *.mdb. MS Access korzysta ze sterownika [Microsoft Access Database Engine], który można pobrać ze strony Microsoft <a href="https://www.microsoft.com/en-us/download/details.aspx?id=13255">https://www.microsoft.com/en-us/download/details.aspx?id=13255</a> (dostęp 19.10.2016).</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="500" height="357" src="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-2.png" class="vc_single_image-img attachment-large" alt="odbc-dsn-windows-32bit-2" title="odbc-dsn-windows-32bit-2" srcset="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-2.png 500w, https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-2-300x214.png 300w" sizes="(max-width: 500px) 100vw, 500px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Na ekranie ustawień należy zdefiniować nazwę źródła danych, która zostanie użyta w oprogramowaniu SCADA jako parametr DSN. Po naciśnięciu przycisku [Wybierz] należy wskazać plik mdb bazy danych. Pozostałe opcje należy pozostawić bez zmiany. Konfigurację należy zapisać, naciskając przycisk [OK].</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="478" height="320" src="https://induprogress.pl/wp-content/uploads/2025/10/integracja-oprogramowania-SCADA-3.png" class="vc_single_image-img attachment-large" alt="integracja oprogramowania SCADA-3" title="integracja oprogramowania SCADA-3" srcset="https://induprogress.pl/wp-content/uploads/2025/10/integracja-oprogramowania-SCADA-3.png 478w, https://induprogress.pl/wp-content/uploads/2025/10/integracja-oprogramowania-SCADA-3-300x201.png 300w" sizes="(max-width: 478px) 100vw, 478px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Ustawienie DSN dla MySQL</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Z listy dostępnych sterowników należy wybrać sterownik obsługujący bazę MySQL. MySQL korzysta ze sterownika ODBC ze strony MySQL <a href="https://dev.mysql.com/downloads/connector/odbc/">https://dev.mysql.com/downloads/connector/odbc/</a> (dostęp 19.10.2016).</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="500" height="356" src="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-4.png" class="vc_single_image-img attachment-large" alt="odbc-dsn-windows-32bit-4" title="odbc-dsn-windows-32bit-4" srcset="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-4.png 500w, https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-4-300x214.png 300w" sizes="(max-width: 500px) 100vw, 500px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Na ekranie ustawień należy zdefiniować nazwę źródła danych (Data Source Name), która zostanie użyta w oprogramowaniu SCADA jako parametr dsn. Dodatkowo należy podać adres bazy danych, nazwę i hasło użytkownika oraz wybrać bazę. Połączenie można sprawdzić, naciskając przycisk [Test]. W przypadku poprawnej konfiguracji powinna się pojawić informacja „Connection Successful”. Konfigurację należy zapisać, naciskając przycisk [OK].</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="435" height="413" src="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-5.png" class="vc_single_image-img attachment-large" alt="odbc-dsn-windows-32bit-5" title="odbc-dsn-windows-32bit-5" srcset="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-5.png 435w, https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-5-300x285.png 300w" sizes="(max-width: 435px) 100vw, 435px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Ustawienie DSN dla MS SQL Server 2012 Express (LocalDB)</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Z listy dostępnych sterowników należy wybrać SQL Server Native Client 11.0. Na poniższych rysunkach przedstawiono kolejne kroki konfiguracji, które zapewniły poprawną komunikację z bazą danych.</p>

		</div>
	</div>
<div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="582" height="403" src="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-6.jpg" class="vc_single_image-img attachment-large" alt="odbc-dsn-windows-32bit-6" title="odbc-dsn-windows-32bit-6" srcset="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-6.jpg 582w, https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-6-300x208.jpg 300w" sizes="(max-width: 582px) 100vw, 582px" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="582" height="403" src="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-7.jpg" class="vc_single_image-img attachment-large" alt="odbc-dsn-windows-32bit-7" title="odbc-dsn-windows-32bit-7" srcset="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-7.jpg 582w, https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-7-300x208.jpg 300w" sizes="(max-width: 582px) 100vw, 582px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="582" height="403" src="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-8.jpg" class="vc_single_image-img attachment-large" alt="odbc-dsn-windows-32bit-8" title="odbc-dsn-windows-32bit-8" srcset="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-8.jpg 582w, https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-8-300x208.jpg 300w" sizes="(max-width: 582px) 100vw, 582px" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="582" height="403" src="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-9.jpg" class="vc_single_image-img attachment-large" alt="odbc-dsn-windows-32bit-9" title="odbc-dsn-windows-32bit-9" srcset="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-9.jpg 582w, https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-9-300x208.jpg 300w" sizes="(max-width: 582px) 100vw, 582px" /></div>
		</figure>
	</div>
</div></div></div></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Definicja bazy danych w SCADA</h2><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>W KingSCADA w kategorii [Universal DataSource] jest [ODBC DataSource].</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="165" height="76" src="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-10.jpg" class="vc_single_image-img attachment-large" alt="odbc-dsn-windows-32bit-10" title="odbc-dsn-windows-32bit-10" /></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>W KingView w oknie TouchExplorer jest dostępny [SQL access manager].</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="157" height="57" src="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-11.png" class="vc_single_image-img attachment-large" alt="odbc-dsn-windows-32bit-11" title="odbc-dsn-windows-32bit-11" /></div>
		</figure>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Jeżeli z poziomu Scady ma być tworzona tabela, należy zdefiniować jej szablon przez [Table template]. Odczytywanie i zapisywanie danych wymaga ustawienia powiązania między kolumnami bazy danych a tagami. Mapowanie takie tworzy się narzędziem [Bind list]. Nie dotyczy to dostępu do danych w KingSCADA z wykorzystaniem funkcji z kategorii Dataset.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Szablon tabeli</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Szablon tabeli jest definiowany w [Table template]. W oknie można ustawić nazwę szablonu [Table Template Name], nazwę kolumny [Field Name], typ [Tag Type], rozmiar [Tag Length], czy ma być indeksem [Index Type] oraz czy może być pusta NULL. Aby dodać kolumnę do listy, należy nacisnąć przycisk [Add Item]. Naciśnięcie przycisk [OK] zapisuje bieżącą postać szablonu.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="464" height="397" src="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-12.png" class="vc_single_image-img attachment-large" alt="odbc-dsn-windows-32bit-12" title="odbc-dsn-windows-32bit-12" srcset="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-12.png 464w, https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-12-300x257.png 300w" sizes="(max-width: 464px) 100vw, 464px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Mapowanie kolumn na tagi</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Mapowanie kolumn na tagi jest niezbędne przy wymianie danych między SCADA a bazą danych, gdy wykorzystywane są wbudowane funkcje SQL. W oknie ustawień można zdefiniować nazwę mapy [Bind List Name]. Poniżej nazwie kolumny [Field Name] przyporządkowuje się tag [Tag]. Aby dodać element listy, należy nacisnąć przycisk [Add Item]. Zmiany zatwierdza się naciśnięciem przycisku [OK].</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="470" height="398" src="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-13.png" class="vc_single_image-img attachment-large" alt="odbc-dsn-windows-32bit-13" title="odbc-dsn-windows-32bit-13" srcset="https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-13.png 470w, https://induprogress.pl/wp-content/uploads/2025/10/odbc-dsn-windows-32bit-13-300x254.png 300w" sizes="(max-width: 470px) 100vw, 470px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Połączenie i wymiana danych</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Oprogramowanie WellinTech umożliwia wykonywanie operacji na bazie danych z wykorzystaniem wbudowanych funkcji oraz kontrolek ActiveX.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Wbudowane funkcje</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>W celu korzystania z bazy danych należy zdefiniować tag identyfikujący połączenie oraz po jednym tagu dla każdej kolumny tabeli (tagi wykorzystane w mapowaniu [Bind List]). Dla programisty są dostępne podstawowe operacje na bazie danych. Nazwy tych funkcji zaczynają się od „SQL”. Podstawową funkcją jest SQLConnect(DeviceID, ConnParams), która nawiązuje połączenie.</p>
<p>Funkcja przyjmuje dwa parametry:</p>
<ul>
<li>DeviceID – identyfikator połączenia</li>
<li>ConnParams – ciąg parametrów połączenia zawierający DSN i opcjonalnie nazwę, hasło użytkownika</li>
</ul>
<p>W przypadku KingSCADA występuje dodatkowa kategorii Dataset, dla której nie jest potrzebne mapowanie, odczytywane dane są przechowywane w pamięci w formie tabeli. Do każdej komórki można się odwołać poprzez podanie numeru wiersza i kolumny.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Podsumowanie</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Oprogramowanie SCADA firmy WellinTech umożliwia zapis, odczyt, edycję danych w zewnętrznych bazach danych. Jest to użyteczne w przypadku integrowania systemów automatyki przemysłowej z zewnętrznymi systemami informatycznymi.</p>
<p>Zapraszamy do zapoznania się z ofertą oprogramowania SCADA.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><em>Opublikowano: 18 września 2017</em></p>

		</div>
	</div>
</div></div></div></div>
</div><p>Artykuł <a href="https://induprogress.pl/artykuly-techniczne/integracja-oprogramowania-scada-z-bazami-danych-przez-interfejs-odbc/">Integracja oprogramowania SCADA z bazami danych przez interfejs ODBC</a> pochodzi z serwisu <a href="https://induprogress.pl">Induprogress</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://induprogress.pl/artykuly-techniczne/integracja-oprogramowania-scada-z-bazami-danych-przez-interfejs-odbc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
