<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Archiwa VFD-E - Induprogress</title>
	<atom:link href="https://induprogress.pl/tag/vfd-e/feed/" rel="self" type="application/rss+xml" />
	<link>https://induprogress.pl/tag/vfd-e/</link>
	<description></description>
	<lastBuildDate>Fri, 13 Mar 2026 11:07:26 +0000</lastBuildDate>
	<language>pl-PL</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://induprogress.pl/wp-content/uploads/2024/10/fav-100x100.png</url>
	<title>Archiwa VFD-E - Induprogress</title>
	<link>https://induprogress.pl/tag/vfd-e/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Sterowanie stanem wejść cyfrowych w falownikach serii VFD-E z wykorzystaniem komunikacji z protokołem Modbus</title>
		<link>https://induprogress.pl/artykuly-techniczne/sterowanie-stanem-wejsc-cyfrowych-w-falownikach-serii-vfd-e-z-wykorzystaniem-komunikacji-z-protokolem-modbus/</link>
					<comments>https://induprogress.pl/artykuly-techniczne/sterowanie-stanem-wejsc-cyfrowych-w-falownikach-serii-vfd-e-z-wykorzystaniem-komunikacji-z-protokolem-modbus/#respond</comments>
		
		<dc:creator><![CDATA[Aleksandra Puzon]]></dc:creator>
		<pubDate>Thu, 20 Nov 2025 10:40:06 +0000</pubDate>
				<category><![CDATA[Artykuły techniczne]]></category>
		<category><![CDATA[Technika napędowa]]></category>
		<category><![CDATA[falownik]]></category>
		<category><![CDATA[falowniki]]></category>
		<category><![CDATA[modbus]]></category>
		<category><![CDATA[VFD-E]]></category>
		<guid isPermaLink="false">https://induprogress.pl/?p=28380</guid>

					<description><![CDATA[<p>Niektóre aplikacje wymagają by przy jak najmniejszej ilości okablowania wykorzystywać funkcje wyzwalane przez</p>
<p>Artykuł <a href="https://induprogress.pl/artykuly-techniczne/sterowanie-stanem-wejsc-cyfrowych-w-falownikach-serii-vfd-e-z-wykorzystaniem-komunikacji-z-protokolem-modbus/">Sterowanie stanem wejść cyfrowych w falownikach serii VFD-E z wykorzystaniem komunikacji z protokołem Modbus</a> pochodzi z serwisu <a href="https://induprogress.pl">Induprogress</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" class="vc_single_image-img " src="https://induprogress.pl/wp-content/uploads/2024/11/artykuly-techniczne-banner.jpg" width="1080" height="280" alt="artykuły techniczne induprogress" title="artykuły techniczne banner" loading="lazy" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">Sterowanie stanem wejść cyfrowych w falownikach serii VFD-E</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Niektóre aplikacje wymagają by przy jak najmniejszej ilości okablowania wykorzystywać funkcje wyzwalane przez wejścia cyfrowe urządzenia. W takim przypadku można skorzystać z opcji wyzwalania danych wejść cyfrowych po komunikacji. Sposób ten pozwala na zaoszczędzenie wyjść cyfrowych urządzenia sterującego oraz ogranicza ilość niezbędnego okablowania do minimum.</p>

		</div>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">1. Zmiana statusu wejścia MI</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>W pierwszej kolejności należy zmienić status danego wejścia MI. Domyślnie każde z wejść jest typu zewnętrznego (External) zaś w parametrze falownika 4.27 istnieje możliwość zmiany typu na wewnętrzny (Internal). Zmieniając typ wejścia na INTERNAL możliwa jest zmiana stanu wejścia po komunikacji, za pomocą wewnętrznego PLC, a także z klawiatury panelu cyfrowego. Aby zmienić status danego wejścia w parametrze 4.27 należy wpisać decymalną wartość zgodną z poniższym schematem:</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="645" height="284" src="https://induprogress.pl/wp-content/uploads/2025/11/Sterowanie-stanem_1.png" class="vc_single_image-img attachment-large" alt="Sterowanie stanem_1" title="Sterowanie stanem_1" srcset="https://induprogress.pl/wp-content/uploads/2025/11/Sterowanie-stanem_1.png 645w, https://induprogress.pl/wp-content/uploads/2025/11/Sterowanie-stanem_1-300x132.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/Sterowanie-stanem_1-600x264.png 600w" sizes="(max-width: 645px) 100vw, 645px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Przykładowo, aby zmienić status wejść MI5 oraz MI6 na INTERNAL do parametru 4.27 wpisujemy wartość 2^4 + 2^5=16+32=48.</p>

		</div>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">2. Zmiana stanu wejścia typu INTERNAL</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Zmianę stanu wejścia typu INTERNAL możemy realizować przez zmianę parametru 4.28. Wpisując odpowiednią wartość (rysunek poniżej) zmieniamy stan danego wejścia.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="645" height="284" src="https://induprogress.pl/wp-content/uploads/2025/11/Sterowanie-stanem_2.png" class="vc_single_image-img attachment-large" alt="Sterowanie stanem_2" title="Sterowanie stanem_2" srcset="https://induprogress.pl/wp-content/uploads/2025/11/Sterowanie-stanem_2.png 645w, https://induprogress.pl/wp-content/uploads/2025/11/Sterowanie-stanem_2-300x132.png 300w, https://induprogress.pl/wp-content/uploads/2025/11/Sterowanie-stanem_2-600x264.png 600w" sizes="(max-width: 645px) 100vw, 645px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Przykładowo, by zmienić stan wejść MI5 i MI6 na ON do parametru 4.28 wpisujemy wartość 2^4 + 2^5=16+32=48. Dodatkowo zmiana tego parametru (czyli zmiana stanu wejść cyfrowych) jest możliwa podczas pracy falownika.</p>

		</div>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">3. Wymiana danych PLC z falownikiem przez Modbus</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Wymianę danych PLC z falownikiem przez Modbus realizujemy w oprogramowaniu ISPSoft wykorzystując bloczek MODRW.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="407" height="188" src="https://induprogress.pl/wp-content/uploads/2025/11/Sterowanie-stanem_3.png" class="vc_single_image-img attachment-large" alt="Sterowanie stanem_3" title="Sterowanie stanem_3" srcset="https://induprogress.pl/wp-content/uploads/2025/11/Sterowanie-stanem_3.png 407w, https://induprogress.pl/wp-content/uploads/2025/11/Sterowanie-stanem_3-300x139.png 300w" sizes="(max-width: 407px) 100vw, 407px" /></div>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Parametry funkcji uzupełniamy w następujący sposób:</p>
<p>S1 – adres urządzenia z którym chcemy się połączyć<br />
S2 – kod funkcji modbus: 6- zapis jednego słowa<br />
S3 – modbusowy adres rejestru, w który chcemy wpisać daną<br />
S – rejestr przechowujący dane które chcemy wpisać do urządzenia<br />
n – ilość rejestrów które chcemy zapisać korzystając z instrukcji MODRW</p>
<p>Aby zmieniać stan danego wejścia należy wpisywać odpowiednie wartości do parametru falownika 4.28. Aby uzyskać odpowiadający adres modbusowy należy obie części adresu parametru zamienić na system szesnastkowy.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="285" height="225" src="https://induprogress.pl/wp-content/uploads/2025/11/Sterowanie-stanem_4.png" class="vc_single_image-img attachment-large" alt="Sterowanie stanem_4" title="Sterowanie stanem_4" /></div>
		</figure>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper"><h2 style="text-align: left" class="vc_custom_heading">4. Przypisanie funkcji do wejścia cyfrowego</h2>
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Do danego wejścia cyfrowego można przypisać jedną z dostępnych funkcji. Przypisanie funkcji odbywa się poprzez wpisanie numeru odpowiadającego danej funkcji do parametrów 04.05~04.08, które definiują wejścia MI3~MI6.</p>
<p>Spis dostępnych funkcji umieszczono w tabeli poniżej:</p>
<p>Nr – Opis funkcji<br />
0 – Brak funkcji<br />
1 – Wybór prędkości predefiniowanej 1<br />
2 – Wybór prędkości predefiniowanej 2<br />
3 – Wybór prędkości predefiniowanej 3<br />
4 – Wybór prędkości predefiniowanej 4<br />
5 – Reset zewnętrzny<br />
6 – Blokada przyspieszania/hamowania<br />
7 – Wybór czasu przyspieszania/hamowania<br />
8 – Ruch w trybie JOG<br />
9 – Zewnętrzna blokada napędu<br />
10 – Zwiększanie częstotliwości zadanej<br />
11 – Zmniejszanie częstotliwości zadanej<br />
12 – Wyzwalanie wewnętrznego licznika<br />
13 – Resetowanie wewnętrznego licznika<br />
14 – Wywołanie błędu awarii zewnętrznej EF<br />
15 – Wyłączenie regulatora PID<br />
16 – Wyjście Shutoff Stop<br />
17 – Blokada zmiany parametrów<br />
18 – Wybór źródła komend sterujących –wejścia wielofunkcyjne<br />
19 – Wybór źródła komend sterujących – panel cyfrowy<br />
20 – Wybór źródła komend sterujących – interfejs komunikacyjny<br />
21 – Zmiana kierunku obrotów FWD/REV<br />
22 – Wybór drugiego źródła komendy częstotliwości</p>
<p>&nbsp;</p>
<p>Dzięki sterowaniu wejściami przez komunikację, możemy wyzwalać wybraną funkcję bez fizycznego podpięcia do wejścia cyfrowego. Wszystkie niezbędne informacje, dokładny opis wykorzystanych parametrów oraz funkcji znajdują się w instrukcji obsługi falownika <strong><a href="https://induprogress.pl/kategoria-produktu/technika-napedowa/przemienniki-czestotliwosci/falowniki-serii-vfd-e/">VFD-E</a></strong>.</p>

		</div>
	</div>
<div class="vc_empty_space"   style="height: 20px"><span class="vc_empty_space_inner"></span></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><em>Opublikowano: 10 października 2016</em></p>

		</div>
	</div>
</div></div></div></div>
</div><p>Artykuł <a href="https://induprogress.pl/artykuly-techniczne/sterowanie-stanem-wejsc-cyfrowych-w-falownikach-serii-vfd-e-z-wykorzystaniem-komunikacji-z-protokolem-modbus/">Sterowanie stanem wejść cyfrowych w falownikach serii VFD-E z wykorzystaniem komunikacji z protokołem Modbus</a> pochodzi z serwisu <a href="https://induprogress.pl">Induprogress</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://induprogress.pl/artykuly-techniczne/sterowanie-stanem-wejsc-cyfrowych-w-falownikach-serii-vfd-e-z-wykorzystaniem-komunikacji-z-protokolem-modbus/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
